Các lỗi thường gặp

Code :
  • Code: 116-362
  • Description: PCI Bus #0 Host Bridge Controller Error Cause: PCI Bus #0 Host Bridge Controller Error. (Connected with Remora EX port)
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
  • Code: 116-363
  • Description: PCI Bus #1 Host Bridge Controller Error Cause: PCI Bus #1 Host Bridge Controller Error. (Connected with Remora EX port.)
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
  • Code: 116-364
  • Description: Timer Fail Cause: Timer error is detected.
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, set the RTC correctly.
  • Code: 116-366
  • Description: PCI Bus #1 Error Detected> Cause: PCI Bus #1 Uncorrectable Error Detected. (Connected with RemoraEX(x1 port))
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
  • Code: 116-368
  • Description: PCI Error Messages received from Bus #0 - Device #1 Cause: Remora EX PCI x1 port Error. (Device ID 0x65 (x1))
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
  • Code: 116-369
  • Description: PCI Error Messages received from Bus #0 - Device #0 Cause: Remove EX PCI x4 port Error. (Device ID 0x64 (x4))
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
  • Code: 116-390
  • Description: ESS NVRAM1 SIZE And ID Check Fail Cause: Detected by consistency check between NVRAM size requested by the system and actual size and consistency check of ID recorded at the first power-on.
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
  • Code: 116-396
  • Description: Fatal Error Related to Maillib Other Errors (of File 2 Net Library) Cause: S/W bug.
  • Remedy: 1. Turn the power Off and On to check that the error recurs. 2. Perform the following in sequence • " Network System Fault Check" • " Network-related Details Check Flow" 3. Update to the latest F/W. 4. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
‹ First  < 21 22 23 24 25 26 27 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục