Description: Nup Paper direction mismatch. The paper orientation of the document and the tray are not aligned during Nup.
Remedy: • Press the [Stop] button on the Control Panel. • Press the [Paper Supply] button on the Control Panel. • Press the [Special Copy] button on the Control Panel. • Press the [Original Size Input] button on the Control Panel. • Press the [Clear All] button on the Control Panel.
Description: • MCU-STM comm. error. A communication failure has occurred between the MCU and the Tray Module.
Remedy: • Turn the power OFF then ON. • Check for any open circuit or short circuit between the STM connectors. • Replace the STM PWB (PL 11.5) and the AIOC PWB (PL 8.1) in that order.
Description: Toner Cartridge was PRENEAR empty. The toner cartridge is low.
Remedy: • Refill the toner. • Foreign matter on the sensor. • Check that the Toner Empty Sensor and the LVPS J509-1-4 ( P/J509) pins are connected securely with good electrical contact. If there is no problem, replace the Toner Empty Sensor (PL 4.2). • Replace the AIOC PWB (PL 8.1) .
Description: Toner Empty. The Toner Cartridge is empty.
Remedy: I/O Diagnostic Codes [09-07] Toner Empty Sensor Check Items: • Refill the toner. • Foreign matter on the sensor. • Check that the Toner Empty Sensor and the LVPS J509 ( P/J509) 1-4 pins are connected securely with good electrical contact. If there is no problem, replace the Toner Empty Sensor (PL 4.2). • Replace the AIOC PWB (PL 8.1) .
Description: No Drum Cartridge. Unable to detect the Drum Cartridge.
Remedy: I/O Diagnostic Codes [09-02] Drum Cartridge Check Items: • Turn the power OFF then ON. • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Drum Cartridge (PL 4.1) . – Wire between Drum Cartridge P610-7 ( P610) and AIOC PWB J402-1 ( P/J402) – Wire between Drum Cartridge P610-3 and AIOC PWB J402-4 – Wire between Drum Cartridge P610-2 and AIOC PWB J402-5 – Wire between Drum Cartridge P610-5 and AIOC PWB J402-2 – Wire between Drum Cartridge P610-4 and AIOC PWB J402-3 – Wire between Drum Cartridge P610-1 and AIOC PWB J402-6 • Replace the Drum Cartridge (PL 4.1) and the AIOC PWB (PL 8.1) in that order.
Description: Drum CRUM comm. Error. The AIOC PWB is unable to communicate with the Drum Cartridge.
Remedy: I/O Diagnostic Codes • [09-02] Drum Cartridge Check Items: • Turn the power OFF then ON. • Check that the following wires are connected securely with good electrical contact. If there is no problem, replace the Drum Cartridge (PL 4.1) . – Wire between Drum Cartridge P610-7 ( P610) and AIOC PWB J402-1 ( P/J402) – Wire between Drum Cartridge P610-3 and AIOC PWB J402-4 – Wire between Drum Cartridge P610-2 and AIOC PWB J402-5 – Wire between Drum Cartridge P610-5 and AIOC PWB J402-2 – Wire between Drum Cartridge P610-4 and AIOC PWB J402-3 – Wire between Drum Cartridge P610-1 and AIOC PWB J402-6 • Replace the Drum Cartridge (PL 4.1) and the AIOC PWB (PL 8.1) in that order.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.