Description: IISS EEPROM Failure BSD-Reference: CH 3.1. Error in writing on or communicatiing with the EEPROM.
Remedy: Switch off the machine power then switch on the power. The problem is solved. Y↓N→Replace the SLCC PWB (AIOC/Network PWB). (PL 8.1) Problem is resolved.
Code: 062-360
Description: Carriage Position Fail BSD-Reference: CH 6.2. Detected no input of Regi Sensor when carriage was working or detected the failure of the Regi Sensor position, or detected the failure of the IIT Regi Sensor level.
Remedy: Check that the Lamp Carriage can move freely and has no loose cables. The Lamp Carriage and cables are good. Y↓N→Repair the Lamp Carriage. Enter the Diagnostic Mode. Enter Component Control Code [62-212]. Check the operation of the IIT Regi Sensor. The Regi Sensor is good. Y↓N→Reseat the Regi Sensor connector. Check the wiring for proper operation and repair if necessary. Replace the Regi Sensor. (PL 10.6) Enter the Diagnostic Mode. Enter Component Control Code [05-22]. The Carriage moves in the scan direction. Y↓N→Check the connector of the Carriage Motor and repair if necessary. Replace the Carriage Motor. (PL 10.6) Replace the SLCC PWB (AIOC/Network PWB). (PL 8.1)
Code: 062-371
Description: Lamp Illumination Fail BSD-Reference: CH 6.1. Detected incufficient light provided from the Lamp to the CCD.
Remedy: Check for any obstructions in the optical path between the lamp, the lens or the mirror. The optical path is clear of any obstructions. Y↓N→Remove the obstuctions. Check that the White Color Correction Plate (Reflector) is in place and not deterioarated. (PL 10.6) The White Color Correction Tape is good. Y↓N→Clean or replace the White Color Correction Plate. (PL 10.6) Enter the Diagnostic Mode. Enter Component Control Code [62-02]. The Illumination Lamp is good. Y↓N→Check that the Lamp harness is properly connected and repair if necessary. Replace the Illumination Lamp. Replace the SLCC PWB (AIOC/Network PWB). (PL 8.1)
Code: 062-380
Description: AGC Failure BSD-Reference: CH 6.2. Control logic has detected insufficient light from the Illumination Lamp during AGC (Automatic Gain Congrol) of the auto IIT Calibration at Start.
Remedy: Check for any obstructions in the optical path. Clean the Mirror, lens and the white balance strip. Switch off the power then switch it on again. The problem has been resolved. Y↓N→Enter the Diagnostic Mode. Enter Component Control Code [62-02]. The lamp is good. Y↓N→Check that the Lamp harness is properly connected and repair if necessary. Replace the Illumination Lamp. Replace the SLCC PWB and (3) EEPROMS (AIOC/Network PWB). (PL 8.1) POPO the machine and retry.
Code: 062-386
Description: AOC Failure BSD-Reference: CH 6.1. Control logic has detected an output defect of the CCD at AOC (Automatic Offset Control) of the auto IIT Calibration at Start.
Remedy: Check the connector P/J410 for proper connection. The problem has been resolved. Y↓N→Replace the SLCC PWB and (3) EEPROMS (AIOC/Network PWB). (PL 8.1) POPO the machine and retry.
Code: 062-392
Description: IPS PWB Memory Fail BSD-Reference: CH 3.1. Control logic has detected RAM malfunction of IISS PWB.
Remedy: Switch off the power then switch it on again. If the problem is not solved, replace the SLCC PWB (AIOC/Network) and the 3 EEPROMs.
Code: 062-393
Description: IPS PWB Fail BSD-Reference: CH 3.1. Control logic has detected a test error or a writing error to the SLCC EEPROMs.
Remedy: Switch off the power then switch it on again. If the problem is not solved, replace the SLCC PWB (AIOC/Network) and the 3 EEPROMs.
Code: C0-1
Description: APS NG Unselected. • Either Tray 1 or STM is in one of the "paper settings is of a size that causes missing image" states when APS is selected during a copy job. • Or, either Tray 1 or STM is "set with paper size that is different from the one specified for the job" when Auto Tray is selected during a print job
Remedy: • Press the [Stop] button on the Control Panel. • Change the paper size of Tray 1 or STM to the one specified by the job.