Description: Fixing unit protection circuit trouble
When an overcurrent has been detected in the IH power supply PCB
Remedy: Replace the IH power supply PCB. Replace the fixing belt unit.
Code: E004-0401
Description: Fixing unit protection circuit trouble
13 V trouble error
Remedy: Check the connection of the connectors of the relay PCB, the IH power supply, the fixing thermoswitch, and replace the fixing unit (fixing thermoswitch OFF), the relay PCB, and the IH power PCB (blowout of the FU261). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
Code: E004-0501
Description: Fixing unit protection circuit trouble
Fixing main thermistor or fixing sub-thermistor 1 or 2 connection error
Remedy: Check the connections of the fixing belt unit connectors. Replace the fixing belt unit.
Code: E004-0502
Description: Fixing unit protection circuit trouble
Pressure main thermistor or pressure sub-thermistor 1 or 2 connection error
Remedy: Check the connections of the pressure belt unit connectors. Replace the pressure belt unit.
Code: E004-0601
Description: Fixing unit protection circuit trouble
IH power supply ID error
Remedy: Check the connection of the connectors of the IH power supply PCB J1009, the DC controller PCB 2 (MAISY) J109, and the relay PCB connector. In the case of not being locked after turning ON the motor
Code: E004-0701
Description: Fixing unit protection circuit trouble
Relay OFF status error
Remedy: Replace the relay PCB.
Code: E007-0001
Description: Fixing belt or pressure belt deviation trouble
Fixing belt deviation trouble (trouble in top belt displacement or in belt deviation sensor)
Remedy: Replace the fixing unit.
Code: E007-0002
Description: Fixing belt or pressure belt deviation trouble
Pressure belt deviation trouble (trouble in bottom belt push-off or in belt deviation sensor)