Description: Pressure belt pressure release error
Pressure belt unit pressure timeout error
Remedy: Replace the fixing pressure release HP sensor. Replace the fixing pressure motor. Replace the DC controller PCB 2 (MAISY).
Code: E012-0001
Description: Drum ITB motor trouble
Drum ITB motor fails to run.
Remedy: Replace the drumITB moter. Replace the DC controller PCB 2 (MAISY). Replace the DCDC converter.
Code: E012-0002
Description: Drum ITB motor trouble
Drum ITB motor runs but then stops running.
Remedy: Replace the drumITB moter. Replace the DC controller PCB 2 (MAISY). Replace the DCDC converter.
Code: E012-0003
Description: Drum ITB motor trouble
When the drum ITB motor fails to stop
Remedy: Replace the drumITB moter. Replace the DC controller PCB 2 (MAISY). Replace the DCDC converter.
Code: E014-0001
Description: Fixing motor error
Drum Unit / Faulty Connection of the Toner Receptacle
Remedy: Replace the drumITB moter. Replace the fixing moter.Replace the DCDC converterAi38VAj. Replace the fixing belt unit.
Code: E014-0001
Description: Fixing motor error
Drum Unit / Faulty Connection of the Toner Receptacle
Remedy: Replace the drumITB moter. Replace the fixing moter.Replace the DCDC converterAi38VAj. Replace the fixing belt unit.
Code: E014-0002
Description: Fixing motor error
When the lock was disengaged after the motor was locked
Remedy: Replace the drumITB moter. Replace the fixing moter.Replace the DCDC converterAi38VAj. Replace the fixing belt unit.
Code: E020-xx20
Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
ATR sensor trouble or a broken/disconnected wire. The drum unit is not installed properly or there is trouble in the unit.
Remedy: Replace the drum unit (check its connections).