Code :
  • Code: E604-0001
  • Description: Memory error
  • Causes: Memory required to start PDL cannot be allocated.
  • Remedy: Check the installed memory, remove and then install the memory, and replace the memory.
  • Code: E616-0001
  • Description: MEAP application is lost.
  • Causes: MEAP application is lost.
  • Remedy: Select Function.gr > MEAP > MEAP FUNCTION = ON, and turn OFF and then ON the main power. * The setting is switched to the following after reboot. Initial screen setting: Native MEAP authentication: Off USB-Host setting: Native CDS-related: Off
  • Code: E616-0002
  • Description: System error
  • Causes: System error
  • Remedy: Execute Setup > Initialize Menu to initialize NVRAM.
  • Code: E730-100A
  • Description: System error
  • Causes: System error
  • Remedy: 1. Turn OFF and then ON the power. 2. Replace the Main Controller PCB.
  • Code: E730-C000
  • Description: An error, such as failure in memory retrieval at initialization, occurred.
  • Causes: An error, such as failure in memory retrieval at initialization, occurred.
  • Remedy: Turning OFF and then ON the main power executes auto recovery.
  • Code: E730-C001
  • Description: An error occurred when accessing the controller.
  • Causes: An error occurred when accessing the controller.
  • Remedy: Turning OFF and then ON the main power executes auto recovery.
  • Code: E730-D000
  • Description: An error, such as failure in memory retrieval at initialization, occurred.
  • Causes: An error, such as failure in memory retrieval at initialization, occurred.
  • Remedy: 1. Turn OFF and then ON the main power. 2. Replace the Main Controller PCB.
  • Code: E730-D001
  • Description: System error
  • Causes: System error
  • Remedy: 1. Turn OFF and then ON the main power. 2. Replace the Main Controller PCB.