Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance 400i — Trang 16/20

Code: E746-0031

Description: Engine ID error
Hardware error
Remedy: 1. Turn OFF and then ON the power.
2. Replace the TPM PCB.

Code: E746-0032

Description: Engine ID error
TPM key mismatch
Remedy: Format the system
Use SST or USB memory to format the HDD, and then execute downloading of the system software. See Chapter 6 Upgrading for details. For reference, the method using USB memory is shown below:
1. Prepare USB memory in which the system software was registered.

Code: E746-0033

Description: Engine ID error
Mismatched data in the TPM
Remedy: Recovery is available if backup of the TPM has been executed.
1. Connect the USB memory in which the TPM key is saved.
2. Management Settings > Data Management > TPM Settings; click [Restore TPM key].
3. Enter the password that was specified at the time of backup work.
4. Once the restore completion screen is displayed, click [OK] and remove the USB memory, and then turn OFF and ON the main power switch.
When backup of the TPM key is not executed
System format is necessary.
Use SST or USB memory to format the HDD, and then download the system software.

Code: E746-0034

Description: TPM auto recovery error
An error occurs when clearing the HDD while the TPM setting is ON
Remedy: The symptom is recovered by turning OFF and then ON the power

Code: E746-0035

Description: TPM version error
TPM which cannot be used in this machine was installed.
Remedy: Install the supported TPM.

Code: E747-1201

Description: PDL rendering error
Image processing IC error
Remedy: 1. Turn OFF and then ON the power (send the data to Inc because running the data which generated an error code causes another error code).
2. Replace Main Controller PCB (PCB2).

Code: E748-2010

Description: Flash PCB error
Unable to find IPL (startup program)
Remedy: Replace the Flash PCB and install the system using SST or USB

Code: E748-2021

Description: Main Controller PCB access error
Necessary H/W on Main Controller PCB is not detected
Remedy: 1. Clean the terminal of Main Controller PCB, and remove and then install Main Controller PCB.
2. Replace Main Controller PCB (PCB2).