Các lỗi thường gặp

Code :
  • Code: E677-0003
  • Description: Print server error
    Error is detected by checking of the mother board at startup of the print server
  • Remedy: 1. Check cable connection and turn ON the power again.
    2. Reinstall the printer server.
  • Code: E711-0001
  • Description: Communication error (retransmission request reception error)
    Communication between the Host Machine and the Finisher was lost.
  • Remedy: 1. Check the installation of the Host Machine and the Finisher.
    2. Check the connector connection between the DC Controller PCB (PCB1) and the Finisher Controller PCB (PCB1).
    3. Replace the Finisher Controller PCB (PCB1).
    4. Replace the DC Controller PCB (PCB1).
  • Code: E713-0000
  • Description: Error in communication with the Finisher (communication retry failure)
    The communication did not connect again although the error retry was executed after failing to communicate with the Finisher.
  • Remedy: 1. Check the installation of the Host Machine and the Finisher.
    2. Check the connector connection between the DC Controller PCB (PCB1) and the Finisher Controller PCB (PCB1).
    3. Replace the Finisher Controller PCB (PCB1).
    4. Replace the DC Controller PCB (PCB1).
  • Code: E716-0000
  • Description: Error in communication with the Cassette Module
    The communication did not connect again although the error retry was executed after failing to communicate with the Cassette Module.
  • Remedy: 1. Check the installation of the Host Machine and the Cassette Module.
    2. Check the connector connection between the DC Controller PCB (PCB1) and the Cassette Module Controller PCB (PCB101).
    3. Replace the Cassette Module Controller PCB (PCB101).
    4. Replace the DC Controller PCB (PCB1).
  • Code: E719-0001
  • Description: Coin vendor error
    Error when the coin vendor is started
    - The Coin Vendor, which must have been connected before the power was turned OFF, is not connected when the power is turned ON
  • Remedy: Check cable connection between the charging management equipment and the host machine.
    While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment.
    (To prevent a misuse by removing the charging management equipment, this error code is displayed.)
  • Code: E719-0002
  • Description: Coin vendor error
    IPC error at coin vendor operation
    - Open circuit of IPC, unable to recover the IPC communication
    - When open circuit of the pickup/delivery signal cable is detected
    - Invalid connection is detected
  • Remedy: Check cable connection between the charging management equipment and the host machine.
    While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment.
    (To prevent a misuse by removing the charging management equipment, this error code is displayed.)
  • Code: E719-0003
  • Description: Coin vendor error
    - Communication error with the coin manager occurs during unit price acquisition at startup.
  • Remedy: Check cable connection between the charging management equipment and the host machine.
    While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment.
    (To prevent a misuse by removing the charging management equipment, this error code is displayed.)
  • Code: E719-0004
  • Description: Coin vendor error
    The coin vendor was connected to a model that does not support the coin vendor
  • Remedy: 1. Disconnect the coin vendor.