Code: E820-0003

Description: Developing Cooling Fan (Rear) (FM8) rotation error
The lock signal was not detected for 5.0 seconds while the Developing Cooling Fan (Rear) (FM8) was being driven. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Developing Cooling Fan (Rear) (FM8) and the DC Controller PCB (PCB1).
2. Replace the Developing Cooling Fan (Rear) (FM8).
3. Replace the DC Controller PCB (PCB1).

Code: E822-0000

Description: Delivery Cooling Fan (Front) (FM3) error
The lock signal was detected for 5.0 seconds while the Delivery Cooling Fan (Front) (FM3) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Delivery Cooling Fan (Front) (FM3) and the DC Controller PCB (PCB1).
2. Replace the Delivery Cooling Fan (Front) (FM3).
3. Replace the DC Controller PCB (PCB1).

Code: E822-0001

Description: Delivery Cooling Fan (Front) (FM3) rotation error
The lock signal was not detected for 5.0 seconds while the Delivery Cooling Fan (Front) (FM3) was being driven. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Delivery Cooling Fan (Front) (FM3) and the DC Controller PCB (PCB1).
2. Replace the Delivery Cooling Fan (Front) (FM3).
3. Replace the DC Controller PCB (PCB1).

Code: E822-0003

Description: Delivery Cooling Fan (Center) (FM2) rotation error
The lock signal was not detected for 5.0 seconds while the Delivery Cooling Fan (Center) (FM2) was being driven. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Delivery Cooling Fan (Center) (FM2) and the DC Controller PCB (PCB1).
2. Replace the Delivery Cooling Fan (Center) (FM2).
3. Replace the DC Controller PCB (PCB1).

Code: E822-0005

Description: Delivery Cooling Fan (Rear) (FM1) rotation error
The lock signal was not detected for 5.0 seconds while the Delivery Cooling Fan (Rear) (FM1) was being driven.
*The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Delivery Cooling Fan (Rear) (FM1) and the DC Controller PCB (PCB1).
2. Replace the Delivery Cooling Fan (Rear) (FM1).
3. Replace the DC Controller PCB (PCB1).

Code: E880-0001

Description: Controller Fan error
Lock of Controller Fan is detected
Remedy: Check if the connector is connected
If the connector is OK, replace Controller Fan.

Code: E881-0001

Description: CPU abnormal temperature rising error
Abnormal temperature of the Main Controller CPU
Remedy: 1. Send cold air to the device. 2. If there is a shielding object around the inlet, remove it to secure enough space. 3. Check the fan, and remove dust or replace the fan if it has an abnormality such as abnormal sound. 4. Replace the Main Controller PCB.

Code: E996-0071

Description: Frequent error avoidance jam (ADF)
Remedy: Depending on the setting of JM-ERR-R in service mode, “010071” jam is displayed as an error.
Collect log and contact to the sales companies.
To cancel the setting, select COPIER> OPTION> FNC-SW> JM-ERR-R, and set JM-ERR-R to 0