Description: UFDI communication error
Communication system error (reception time out error/ checksum error etc.)
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E711-0002
Description: IPC communication error
Communication system error (packet error occurs without the request of initialization)
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E713-0000
Description: Erroneous communication with finisher (retry error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB
Code: E713-0001
Description: Erroneous communication with finisher (transmission retry error)
The communication does not restart by the error retry after the communication failure with the finisher
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E713-0002
Description: Erroneous communication with finisher (transmission data error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E713-0004
Description: Erroneous communication with finisher (reception error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E713-0010
Description: Erroneous communication with finisher (reception error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.
Code: E713-0011
Description: Erroneous communication with finisher (reception error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.