Description: Drum Motor (M1) error
Lock error of the Drum Motor (M1).
Remedy: 1. Check the connection of the Main Driver PCB (PCB2) and the Drum Motor (M1). Motor side: J2138, PCB side: J109 2. Check the voltage of the Drum Motor (M1) J2151. If voltage is 0V, check the connection of the Relay PCB J520. 3. Replace the Drum Motor (M1). 4. Check the gear of the Drum Drive Shaft. If the load is too much, replace the Process Unit and the Drum Drive Unit (Shaft). 5. Replace the Main Driver PCB (PCB2). 6. Replace the DC Controller PCB (PCB1).
Description: Error in Waste Toner Lock Detection Connector disconnection
The Waste Toner Lock Detection Switch (SW5) detects locked state 3 times for 200 msec at power-on.
Remedy: Check the connection of the Waste Toner Lock Detection Switch (SW5) and the Main Driver PCB (PCB2). Switch side: J3050, PCB side: J103
Description: Error in Waste Toner Feed Screw Lock detection
The Waste Toner Lock Detection Switch detects locked state 3 times for 200 msec while the Developing Assembly is driven.
Remedy: 1. Check the Waste Toner Container and the Waste Toner Container Pipe. If toner overflowed from the Waste Toner Container clogs the outlet of the Waste Toner Pipe, remove the clogged toner. After removing it, check that the screw can be seen from the outlet of the pipe. 2. Check the connection of the Waste Toner Lock Detection Switch (SW5) and the Main Driver PCB (PCB2). 3. Check the connection of the Main Driver PCB (PCB2) and the DC Controller PCB (PCB1). Main Controller side: J3050, DC Controller side: J103 4. Replace the Waste Toner Lock Detection Switch (SW5). 5. Replace the Waste Toner Feed Unit. 6. Replace the Main Driver PCB (PCB2). 7. Replace the DC Controller PCB (PCB1). (When the error is still displayed after replacing the Waste Toner Feed Unit and the Main Driver PCB (PCB2).)
Description: Fixing Motor error
Lock error of the Fixing Motor (M3).
Remedy: 1. Check the gear of the Fixing Drive Unit. -> Replace the gear. 2. Replace the Fixing Motor (M3). 3. Check the connection drawer between the Fixing Assembly and the host machine. 4. Replace the Main Driver PCB (PCB2).
Description: ETB disengagement error
Disengagement of the ETB is not completed within the specified period of time.
Remedy: 1. Check the connection of the ETB Disengage Sensor (PS56). Sensor side: J2101, J3270, PCB side: J343 (Duplex Driver PCB (PCB4)) 2. Check the connection of the Duplex Feed Left Motor (M19). Motor side: J2107, J3044 (relay), PCB side: J330 (Duplex Driver PCB (PCB4)) 3. Replace the ETB Disengage Sensor (PS56). 4. Replace the Duplex Feed Left Motor (M19). 5. Replace the Duplex Driver PCB (PCB4). 6. Replace the DC Controller PCB (PCB1). NOTE: Check if the Disengagement Cam is stained. If necessary, clean it. Check if the drive system (gear, Motor, one-way) is failed. If necessary, replace it. Check if the link with the Fixing Feed Handle is failed. If necessary, replace it.
Description: ETB engagement error
Engagement of the ETB is not completed within the specified period of time.
Remedy: 1. Check the connection of the ETB Disengage Sensor (PS55). Sensor side: J2100, J3270, PCB side: J343 (Duplex Driver PCB (PCB4)) 2. Check the connection of the Duplex Feed Left Motor (M19). Motor side: J2107, J3044 (relay), PCB side: J330 (Duplex Driver PCB (PCB4)) 3. Replace the ETB Engage Sensor (PS55). 4. Replace the Duplex Feed Left Motor (M19). 5. Replace the Duplex Driver PCB (PCB4). 6. Replace the DC Controller PCB (PCB1). NOTE: Check if the Disengagement Cam is stained. If necessary, clean it. Check if the drive system (gear, Motor, one-way) is failed. If necessary, replace it. Check if the link with the Fixing Feed Handle is failed. If necessary, replace it.
Description: ETB HP error
Engagement of the ETB was not completed at initialization.
Remedy: If this error occurs at installation, the ETB Disengage Member (Transfer Frame Stopper) may be left unremoved. Refer to the troubleshooting "Remedy to be implemented when the ETB Disengage Member (Transfer Frame Stopper) is left unremoved" in the Service Manual, and check whether the ETB Disengage Member is left unremoved or not and implement appropriate procedure. If this error occurs at times other than installation, follow the following steps to implement check and remedy. 1. Check the connection of the ETB Disengage Sensor (PS56). Sensor side: J2101, J3270, PCB side: J343 (Duplex Driver PCB (PCB4)) 2. Check the connection of the Duplex Feed Left Motor (M19). Motor side: J2107, J3044 (relay), PCB side: J330 (Duplex Driver PCB (PCB4)) 3. Replace the ETB Disengage Sensor (PS56). 4. Replace the Duplex Feed Left Motor (M19). 5. Replace the Duplex Driver PCB (PCB4). 6. Replace the DC Controller PCB (PCB1). NOTE: Check if the Disengagement Cam is stained. If necessary, clean it. Check if the drive system (gear, Motor, one-way) is failed. If necessary, replace it. Check if the link with the Fixing Feed Handle is failed. If necessary, replace it.