Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance 8285 Pro — Trang 44/54

Code: E711-0002

Description: IPC communication error (reception timeout) Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection. Check the connection between DCON side (J462) and Finisher Lattice side (J9043) Finisher Cable 2. Replace the DC Controller PCB.

Code: E711-0004

Description: IPC communication error (checksum error). Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection. Check the connection between DCON side (J462) and Finisher Lattice side (J9043) Finisher Cable 2. Replace the DC Controller PCB.

Code: E711-0020

Description: IPC communication error (recovery error). Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection. Check the connection between DCON side (J462) and Finisher Lattice side (J9043) Finisher Cable 2. Replace the DC Controller PCB.

Code: E711-0040

Description: IPC communication error (serial error). Communication between the host machine and the Finisher was lost
Remedy: 1. Check the cable connection. Check the connection between DCON side (J462) and Finisher Lattice side (J9043) Finisher Cable 2. Replace the DC Controller PCB.

Code: E713-0001

Description: Finisher IPC communication error (retransmission request reception error). Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.

Code: E713-0002

Description: Finisher IPC communication error (reception timeout). Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.

Code: E713-0004

Description: Finisher IPC communication error (checksum error). Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.

Code: E713-0020

Description: Finisher IPC communication error (recovery error). Communication between the host machine and the Finisher was lost.
Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.