Code: E227-0002

Description: Power supply (24V) error. 24V port is OFF when a job is started.
Remedy: 1. Connector disconnection/open circuit of the Reader Power Supply. 2. Failure of power supply.

Code: E227-0003

Description: Power supply (24V) error. 24V port is OFF when a job is ended.
Remedy: 1. Connector disconnection/open circuit of the Reader Power Supply. 2. Failure of power supply.

Code: E227-0004

Description: Power supply (24V) error. 24V port is OFF when loading.
Remedy: 1. Connector disconnection/open circuit of the Reader Power Supply. 2. Failure of power supply.

Code: E227-0101

Description: Power supply (24V) error. 24V port is OFF when the power of DADF is turned ON.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.

Code: E227-0102

Description: Power supply (24V) error. 24V port is OFF when a job is started in the DADF.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.

Code: E227-0103

Description: Power supply (24V) error. 24V port is OFF when a job is ended in the DADF.
Remedy: 1. Connection error between the DADF Driver PCB (PCB1) and the Reader Controller PCB (PCB1). 2. Connector disconnection/open circuit of the Reader Power Supply. 3. Failure of power supply.

Code: E240-0000

Description: Communication error between Main Controller and DC Controller. Communication error occurs between the CPU of the Main Controller PCB and the DC Controller PCB (PCB1).
Remedy: 1. Check the connection of the Main Controller PCB and the DC Controller PCB (PCB1). Main Controller side: J712, DC Controller side: J442 2. Replace the DC Controller PCB (PCB1). 3. Replace the Main Controller PCB.

Code: E240-0001

Description: 3 minutes passed with pickup request waiting status. It was detected that 3 minutes passed with pickup request waiting status.
Remedy: 1. Check the connection of the Connector. 2. Check the connection of the Sub PCB in the Main Controller PCB 1 Box. 3. Check the connections of the DC Controller PCB and the Main Controller PCB 1. Replace the PCB(s) if necessary.