Description: Scanner communication error
DDI-S communication error
Remedy: 1. Check the connector connection with the scanner 2. Check the power of the scanner > Is initialization executed at startup? 3. Replace the Reader Relay PCB, the Scanner PCB or Main Controller PCB 2
Description: Scanner communication error
When a scanner is detected from the printer model for the first time (It is recorded in the history, but “Turn OFF and then ON the power again” is displayed on the UI.)
Description: Printer communication error
A communication error between the DC Controller PCB and the Main Controller PCB 2 is detected at startup.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Flexible Cable between the DC Controller PCB (UN9) and the Main Controller PCB 2. 3. Replace the Flexible Cable. 4. Check the power of the DC Controller PCB (UN9). (Check if the initialization operation is executed at startup.) 5. Replace the DC Controller PCB (UN9). 6. Replace the Main Controller PCB 2.
Description: Printer communication error
A communication error between the DC Controller PCB and the Main Controller PCB 2 is detected at startup.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Flexible Cable between the DC Controller PCB (UN9) and the Main Controller PCB 2. 3. Replace the Flexible Cable. 4. Check the power of the DC Controller PCB (UN9). (Check if the initialization operation is executed at startup.) 5. Replace the DC Controller PCB (UN9). 6. Replace the Main Controller PCB 2.
Description: Printer communication error
A communication error between the DC Controller PCB and the Main Controller PCB 2 is detected at startup.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Flexible Cable between the DC Controller PCB (UN9) and the Main Controller PCB 2. 3. Replace the Flexible Cable. 4. Check the power of the DC Controller PCB (UN9). (Check if the initialization operation is executed at startup.) 5. Replace the DC Controller PCB (UN9). 6. Replace the Main Controller PCB 2.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.