Các lỗi thường gặp

Code :
  • Code: E020-03C0-05
  • Description: Error in take-up of Sealing Member (C)
  • Causes: The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (C).
  • Remedy: Check/replace the Drum Unit (C).
  • Code: E020-03F0-05
  • Description: Error in toner density (C) at communication failure of the Drum Unit Memory PCB (C)
  • Causes: Communication between the DC Controller PCB and the Drum Unit Memory PCB (C) was not available, and the output value (SigR) of the ATR Sensor (C) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times.
  • Remedy: [Related parts] - Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Y) (UN10/ J6003) - Drum Unit (C) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If the Drum Unit Memory PCB (C) is soiled, clean it with a blower. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E020-04A8-05
  • Description: ATR Sensor (Bk) output error
  • Causes: The output value of the ATR Sensor (Bk) in the Drum Unit (Bk) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times during printing.
  • Remedy: [Related parts] R1.00 - Harness between the ATR Sensor (Bk) (UN37/J6024) and the Drum Unit Memory PCB (Bk) (UN15/J6014) - Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/ J6004) - ATR Sensor (Bk) (UN37) - Drum Unit (Bk) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E020-04B8-05
  • Description: ATR Sensor (Bk) output error
  • Causes: a. The output value of the ATR Sensor (Bk) in the Drum Unit (Bk) did not fall within the range from 10 or higher to 990 or less for 2 consecutive times at initialization. b. The output value did not exceed 140 although the control voltage of the ATR Sensor (Bk) in the Drum Unit (Bk) was increased to 248 or higher, or it did not fall below 140 although the voltage was decreased to 8 at initialization.
  • Remedy: [Related parts] R1.00 - Harness between the ATR Sensor (Bk) (UN37/J6024) and the Drum Unit Memory PCB (Bk) (UN15/J6014) - Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/ J6004) - ATR Sensor (Bk) (UN37) - Drum Unit (Bk) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E020-04C0-05
  • Description: Error in take-up of Sealing Member (Bk)
  • Causes: The patch output value (SigR) failed to be 900 or less during initialization of the Drum Unit (Bk).
  • Remedy: [Remedy] Check/replace the Drum Unit (Bk).
  • Code: E020-04F0-05
  • Description: Error in toner density (Bk) at communication failure of the Drum Unit Memory PCB (Bk)
  • Causes: Communication between the DC Controller PCB and the Drum Unit Memory PCB (Bk) was not available, and the output value (SigR) of the ATR Sensor (Bk) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J162) and the Drum Unit Relay PCB (Bk) (UN11/ J6004) - Drum Unit (Bk) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If the Drum Unit Memory PCB (Bk) is soiled, clean it with a blower. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E021-0001-05
  • Description: Developing Motor error
  • Causes: It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Developing Motor. (The detection timing varies depending on the paper feed conditions.)
  • Remedy: [Related parts] R1.00 - Harness between the Developing Motor (M03/J5703) and the DC Controller PCB (UN04/J142) - Fuse in the DC Controller PCB (UN04/FU4) - Developing Motor (M03) - Main Drive Unit - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB. 2. Measure the both ends of the fuse in the DC Controller PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the Developing Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E021-0002-05
  • Description: Developing Motor error
  • Causes: The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Developing Motor.
  • Remedy: [Related parts] R1.00 - Harness between the Developing Motor (M03/J5703) and the DC Controller PCB (UN04/J142) - Fuse in the DC Controller PCB (UN04/FU4) - Developing Motor (M03) - Main Drive Unit - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harness between the Developing Motor and the DC Controller PCB. 2. Measure the both ends of the fuse in the DC Controller PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the Developing Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES