Các lỗi thường gặp

Code :
  • Code: E074-0000-05
  • Description: Primary Transfer Roller disengagement control error
  • Causes: Signal was not detected although the ITB Pressure Release Switch was turned ON/OFF for 6 times.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J162) and the ITB Pressure Release Switch (SW07/J6005) - Harness between the DC Controller PCB (UN04/J140) and the Primary Transfer Separation Solenoid (SL01/J5708) - Fuse in the DC Controller PCB (UN04/FU07) - ITB Guide Rail - Main Drive Unit - ITB Unit - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the ITB Unit is installed in the machine. 2. Replace the ITB Unit. 3. Check the harness between the DC Controller PCB and the ITB Pressure Release Switch. 4. Check the harness between the DC Controller PCB and the Primary Transfer Separation Solenoid. 5. Measure the both ends of the fuse in the DC Controller PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the ITB Guide Rail (Front/Rear). 2. Replace the Main Drive Unit. 3. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E074-0002-05
  • Description: Error in Primary Transfer Roller operation
  • Causes: The ITB Pressure Release Switch could not detect the engagement operation within the specified period of time at engagement operation of the Primary Transfer Roller.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J162) and the ITB Pressure Release Switch (SW07/J6005) - Harness between the DC Controller PCB (UN04/J140) and the Primary Transfer Separation Solenoid (SL01/J5708) - Fuse in the DC Controller PCB (UN04/FU07) - ITB Guide Rail - Main Drive Unit - ITB Unit - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the ITB Unit is installed in the machine. 2. Replace the ITB Unit. 3. Check the harness between the DC Controller PCB and the ITB Pressure Release Switch. 4. Check the harness between the DC Controller PCB and the Primary Transfer Separation Solenoid. 5. Measure the both ends of the fuse in the DC Controller PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the ITB Guide Rail (Front/Rear). 2. Replace the Main Drive Unit. 3. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E100-0001-05
  • Description: BD error
  • Causes: The BD lock was unlocked although it had been locked once.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Flexible Cable between the Main Controller PCB (UN81/J7002) and the Y/M/C/Bk Laser Driver PCB (UN05/J201) - Interlock Switch 2 (SW03) - Front Cover/Right Cover - Y/M/C/Bk Laser Driver PCB (UN05) - Laser Scanner Unit - DC Controller PCB (UN04) - Main Controller PCB (UN81) - Low Voltage Power Supply PCB (UN01) [Remedy] 1. Check/replace the related harness/cable, connector and parts. 2. After replacement of the Laser Driver PCB, execute "Settings/Registration> Adjustment/ Maintenance> Adjust Image Quality> Auto Correct Color Mismatch". [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E102-0001-05
  • Description: EEPROM error
  • Causes: An error has occurred in EEPROM of the Laser Scanner.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Flexible Cable between the Main Controller PCB (UN81/J7002) and the Y/M/C/Bk Laser Driver PCB (UN05/J201) - Interlock Switch 2 (SW03) - Y/M/C/Bk Laser Driver PCB (UN05) - Laser Scanner Unit - DC Controller PCB (UN04) - Main Controller PCB (UN81) - Low Voltage Power Supply PCB (UN01) [Remedy] 1. Check/replace the related harness/cable, connector and parts. 2. After replacement of the Laser Driver PCB, execute "Settings/Registration> Adjustment/ Maintenance> Adjust Image Quality> Auto Correct Color Mismatch". [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E110-0001-05
  • Description: Scanner Motor error
  • Causes: The speed was not locked by FG control within 10 sec after startup of Scanner Motor.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Flexible Cable between the Main Controller PCB (UN81/J7002) and the Y/M/C/Bk Laser Driver PCB (UN05/J201) - Interlock Switch 2 (SW03) - Front Cover/Right Cover - Y/M/C/Bk Laser Driver PCB (UN05) - Laser Scanner Unit - DC Controller PCB (UN04) - Main Controller PCB (UN81) - Low Voltage Power Supply PCB (UN01) [Remedy] 1. Check/replace the related harness/cable, connector and parts. 2. After replacement of the Laser Driver PCB, execute "Settings/Registration> Adjustment/ Maintenance> Adjust Image Quality> Auto Correct Color Mismatch". [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E110-0002-05
  • Description: Scanner Motor error
  • Causes: The speed was not locked by BD control within 10 sec after startup of Scanner Motor.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Flexible Cable between the Main Controller PCB (UN81/J7002) and the Y/M/C/Bk Laser Driver PCB (UN05/J201) - Interlock Switch 2 (SW03) - Front Cover/Right Cover - Y/M/C/Bk Laser Driver PCB (UN05) - Laser Scanner Unit - DC Controller PCB (UN04) - Main Controller PCB (UN81) - Low Voltage Power Supply PCB (UN01) [Remedy] 1. Check/replace the related harness/cable, connector and parts. 2. After replacement of the Laser Driver PCB, execute "Settings/Registration> Adjustment/ Maintenance> Adjust Image Quality> Auto Correct Color Mismatch". [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E110-0003-05
  • Description: Scanner Motor error
  • Causes: The phase was not locked by BD control within 10 sec after startup of Scanner Motor.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Flexible Cable between the Main Controller PCB (UN81/J7002) and the Y/M/C/Bk Laser Driver PCB (UN05/J201) - Interlock Switch 2 (SW03) - Front Cover/Right Cover - Y/M/C/Bk Laser Driver PCB (UN05) - Laser Scanner Unit - DC Controller PCB (UN04) - Main Controller PCB (UN81) - Low Voltage Power Supply PCB (UN01) [Remedy] 1. Check/replace the related harness/cable, connector and parts. 2. After replacement of the Laser Driver PCB, execute "Settings/Registration> Adjustment/ Maintenance> Adjust Image Quality> Auto Correct Color Mismatch". [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E110-0005-05
  • Description: Scanner Motor error
  • Causes: GBD signal was not detected although a specified period of time had passed after startup.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J112) and the Main Controller PCB (UN81/ J4511) - Main Controller PCB (UN81) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES