Code: E674-000C

Description: Fax Board communication error
A communication error occurred when accessing the modem IC and the port IC used for fax.
Remedy: [Related parts] - Harness between the Fax Board and the Main Controller PCB (UN81/J7013, J7019) - Fax Board - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts.

Code: E674-0010

Description: Fax Board communication error
A communication error occurred when opening the Timer Device used for fax.
Remedy: [Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)

Code: E674-0011

Description: Fax Board communication error
A communication error occurred when starting the Timer Device used for fax.
Remedy: [Remedy] Replace the Main Controller PCB (UN81). (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY)

Code: E674-0100

Description: Fax Board communication error
After completion of fax communication, writing of the communication information (log) failed, and the log could not be read.
Remedy: [Related parts] - HDD (Unit of replacement: HARD DISK DRIVE) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Turn OFF and then ON the main power, and check whether the error is cleared. [Caution] By executing “COPIER> FUNCTION> CLEAR> FXTX-CLR”, job logs in “Status Monitor/Cancel> Send> Log> Fax Transmission Completion Log” are cleared. 2. After deleting the system software using USB memory, reinstall it using SST or a USB memory. 3. After replacing the HDD, execute [4] Clear/Format> [1] Disk Format (HDD format) using SST or a USB memory. 4. Replace the Main Controller PCB.

Code: E674-0200

Description: HDD access error
An error occurred when accessing the HDD.
Remedy: [Related parts] - HDD (Unit of replacement: HARD DISK DRIVE) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Turn OFF and then ON the main power, and check whether the error is cleared. [Caution] By executing “COPIER> FUNCTION> CLEAR> FXTX-CLR”, job logs in “Status Monitor/Cancel> Send> Log> Fax Transmission Completion Log” are cleared. 2. After deleting the system software using USB memory, reinstall it using SST or a USB memory. 3. After replacing the HDD, execute [4] Clear/Format> [1] Disk Format (HDD format) using SST or a USB memory. 4. Replace the Main Controller PCB.

Code: E713-0000

Description: Communication error
The operation was not completed although retry of the communication between the host machine (Dcon) and the Finisher was performed for 3 consecutive times.
Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the connector (CN1/P3/J3) of the Interface Harness is not disconnected. 2. Replace the Finisher Controller PCB. 3. Replace the Interface Harness.

Code: E719-0001

Description: Coin vendor error
The coin vendor which was connected before turning OFF the main power was not connected at power-on.
Remedy: equipment and the host machine [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Reference] When operating the machine without the charging management equipment, execute “COPIER> FUNCTION> CLEAR> ERR”. (It is designed to generate an error to prevent the misuse by removing the charging management equipment.)

Code: E719-0002

Description: Coin vendor error
IPC error while the coin vendor is running. - Open circuit of the IPC Communication Cable, or IPC communication could not be recovered. - Open circuit of the pickup/delivery signal cable was detected. - Invalid connection was detected.
Remedy: [Related parts] Cable between the charging management equipment and the host machine [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Reference] When operating the machine without the charging management equipment, execute “COPIER> FUNCTION> CLEAR> ERR”. (It is designed to generate an error to prevent the misuse by removing the charging management equipment.)
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie