Code: E746-0024-00

Description: Image Analysis Board error
Causes: Failure in behavior of Image Analysis Board (PCB used for PCAM)
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Remove and then install the Image Analysis Board. 2. If the error is not cleared, replace the Image Analysis Board. 3. After replacing the Image Analysis Board, reinstall the firmware of the Image Analysis Board or the system software which version is supported by this model using SST or a USB flash drive.

Code: E746-0031-00

Description: TPM error
Causes: A communication error has occurred between the Main Controller PCB and the TPM PCB at startup.
Remedy: Check/replace the TPM PCB. [Reference] After replacing the TPM PCB, if the TPM key was backed up, restore the key. 1. Connect the USB memory which stores the TPM key. 2. Execute "Settings/Registration> Log In> Management Settings> Data Management> TPM Settings> Restore TPM Key". [CAUTION] Ask the customer to enter "System Manager ID" and "System Manager PIN" when logging in. 3. Enter the password set at backup operation. 4. When the restoration completion screen is displayed, click "OK". Remove the USB memory, and turn OFF and then ON the main power.

Code: E746-0032-00

Description: TPM error
Causes: Mismatch of the TPM key was detected.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Format the HDD and reinstall the system software using SST or a USB flash drive. 2. Replace the TPM PCB. [Reference] After replacing the TPM PCB, if the TPM key was backed up, restore the key. 1. Connect the USB memory which stores the TPM key. 2. Execute "Settings/Registration> Log In> Management Settings> Data Management> TPM Settings> Restore TPM Key". [CAUTION] Ask the customer to enter "System Manager ID" and "System Manager PIN" when logging in. 3. Enter the password set at backup operation. 4. When the restoration completion screen is displayed, click "OK". Remove the USB memory, and turn OFF and then ON the main power.

Code: E746-0033-00

Description: TPM error
Causes: It was detected that data in TPM was inconsistent.
Remedy: If the TPM key was backed up, - Restore the TPM key. 1. Connect the USB memory which stores the TPM key. 2. Execute "Settings/Registration> Log In> Management Settings> Data Management> TPM Settings> Restore TPM Key". [CAUTION] Ask the customer to enter "System Manager ID" and "System Manager PIN" when logging in. 3. Enter the password set at backup operation. 4. When the restoration completion screen is displayed, click "OK". Remove the USB memory, and turn OFF and then ON the main power. If the TPM key was not backed up, - Format

Code: E746-0034-00

Description: TPM auto recovery error
Causes: The error occurred when clearing HDD while TPM setting was ON.
Remedy: It is recovered by turning OFF and then ON the power. If the error is not cleared, format the HDD and reinstall the system software using SST or a USB flash drive.

Code: E746-0035-00

Description: TPM version error
Causes: TPM PCB which cannot be used in this machine was installed.
Remedy: Install the TPM PCB for this model.

Code: E748-2000-00

Description: Main Controller PCB access error
Causes: Main Controller PCB Chip access error.
Remedy: Check/replace the Main Controller PCB (UN81)

Code: E748-2001-00

Description: Main Controller PCB access error
Causes: Main Controller PCB memory access error.
Remedy: Check/replace the Main Controller PCB (UN81)