Code: E806-0300-05

Description: Delivery Cooling Fan error
Causes: The Delivery Cooling Fan did not rotate for the specified period of time since the start of drive.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J151) and the Delivery Cooling Fan (FM03/ J5413) - Delivery Cooling Fan (FM03) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E806-0301-05

Description: Delivery Cooling Fan error
Causes: The Delivery Cooling Fan rotated for more than the specified period of time after the stop of drive.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J151) and the Delivery Cooling Fan (FM03/ J5413) - Delivery Cooling Fan (FM03) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E806-0400-05

Description: Duplex Cooling Fan error
Causes: The Duplex Cooling Fan in the Right Cover did not rotate for the specified period of time since the start of drive.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J122) and the Duplex Cooling Fan (FM04/J5610) - Duplex Cooling Fan (FM04) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E806-0401-05

Description: Duplex Cooling Fan error
Causes: The Duplex Cooling Fan in the Right Cover rotated for more than the specified period of time after the stop of drive.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J122) and the Duplex Cooling Fan (FM04/J5610) - Duplex Cooling Fan (FM04) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E808-0001-05

Description: Zero cross signal detection error
Causes: An electrical trouble caused by zero cross signal error. Frequency between 43 Hz and 57 Hz could not be detected for 5000 msec or longer.
Remedy: [Related parts] R1.00 - Harness between the Low-voltage Power Supply PCB (UN01/J322) and the DC Controller PCB (UN04/J22) - Low-voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E880-0001-00

Description: Controller Cooling Fan error
Causes: It was detected that the Controller Cooling Fan was locked.
Remedy: [Related parts] R1.00 - Controller Cooling Fan - Main Controller PCB (UN81) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: E880-0003-00

Description: Controller Cooling Fan error
Causes: It was detected that the Controller Cooling Fan was locked.
Remedy: [Related parts] R1.00 - Controller Cooling Fan - Main Controller PCB (UN81) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: E880-0005-00

Description: Controller Cooling Fan error
Causes: Fan lock of the HDD Cooling Fan was detected
Remedy: Check if the connector is connected. It the connection is OK, replace the HDD Cooling Fan.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie