Description: Initial installation toner density sensor (C) output upper limit error. When executing developing assembly initial installation mode (COPIER>FUNCTION>INSTALL>INISET-C), the output level does not reach 128 even when control voltage of the toner density sensor became less than 55.
Remedy: 1. Check the connection between the toner density sensor and the DC controller interface PCB. (Connector, Shorting) <Y> sensor side: J7133, J8028, J8087 PCB side: J1240, J8085 <M> sensor side: J7134, J8029, J8088 PCB side: J1240, J8085 <C> sensor side: J7135, J8030, J8089 PCB side: J1240, J8086 <Bk> sensor side: J7146, J8015, J8117 PCB side: J1240, J8086 2. Check whether disconnection or shorting of the toner density sensor occurs or not. 3. Replace the developing assembly.
Code: E020-0334
Description: Initial installation patch (C) density upper limit error. When executing developing assembly initial installation mode (COPIER>FUNCTION>INSTALL>INISET-C), the ATR patch output (SigD) is more than 970.
Remedy: When the value of DISPLAY > DENS >P-LED-DA is large (153(D) or more) and the value of DISPLAY > DENS >P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. This occurs only at a regular timing. When the value of DISPLAY>DENS>DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Check whether the developing assembly and the drum unit are properly installed. 2. Clean the patch sensor. 3. Check the connection between the patch sensor and the DC controller interface PCB. (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1242 4. Check open/close operation of the patch shutter. 5. Clean or replace the ITB. Check whether the ITB belt is dirty or not. If it is dirty, perform cleaning with the following service mode. COPIER>FUNCTION>CLEANING>TBLT-CLN If it is assumed that this error occurred due to scratches on the ITB, replace the ITB. 6. Replace the patch sensor unit. 7. Replace the developing assembly.
Code: E020-0336
Description: Initial installation patch (C) sampling error. When executing developing assembly initial installation mode (COPIER>FUNCTION>INSTALL>INISET-C), the variation before average patch P wave light intensity is more than 100.
Remedy: When the value of DISPLAY > DENS >P-LED-DA is large (153(D) or more) and the value of DISPLAY > DENS >P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. This occurs only at a regular timing. When the value of DISPLAY>DENS>DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Check whether the developing assembly and the drum unit are properly installed. 2. Clean the patch sensor. 3. Check the connection between the patch sensor and the DC controller interface PCB. (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1242 4. Check open/close operation of the patch shutter. 5. Replace the patch sensor unit. 6. Replace the developing assembly.
Code: E020-0340
Description: Initial installation toner density sensor (Bk) output upper limit error. When executing developing assembly initial installation mode (COPIER>FUNCTION>INSTALL>INISET-K), the output level does not reach 128 even when control voltage of the toner density sensor became less than 55.
Remedy: 1. Check the connection between the toner density sensor and the DC controller interface PCB. (Connector, Shorting) <Y> sensor side: J7133, J8028, J8087 PCB side: J1240, J8085 <M> sensor side: J7134, J8029, J8088 PCB side: J1240, J8085 <C> sensor side: J7135, J8030, J8089 PCB side: J1240, J8086 <Bk> sensor side: J7146, J8015, J8117 PCB side: J1240, J8086 2. Check whether disconnection or shorting of the toner density sensor occurs or not. 3. Replace the developing assembly.
Code: E020-0390
Description: Patch (C) density lower limit error. The ATR patch detection output (SigD) is less than 79.
Remedy: When the value of DISPLAY > DENS >P-LED-DA is large (153(D) or more) and the value of DISPLAY > DENS >P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. This occurs only at a regular timing. When the value of DISPLAY>DENS>DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Check whether the developing assembly and the drum unit are properly installed. 2. Clean the patch sensor. 3. Check the connection between the patch sensor and the DC controller interface PCB. (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1242 4. Check open/close operation of the patch shutter. 5. Check whether scratches/dirt are applied to the ITB. If many scratches are found, replace the ITB. If dirt is applied, clean the ITB. In this case, check the ITB cleaning blade at the same time. 6. Replace the patch sensor unit. • • MEMO: This error also occurs when there is not enough toner in the developing assembly. In this case, check the supplyrelated parts in the developing assembly.
Code: E020-0391
Description: Patch (C) density upper limit error. The ATR patch detection output (SigD) is more than 970.
Remedy: When the value of DISPLAY > DENS >P-LED-DA is large (153(D) or more) and the value of DISPLAY > DENS >P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. This occurs only at a regular timing. When the value of DISPLAY>DENS>DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Check whether the developing assembly and the drum unit are properly installed. 2. Clean the patch sensor. 3. Check the connection between the patch sensor and the DC controller interface PCB. (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1242 4. Check open/close operation of the patch shutter. 5. Check whether scratches/dirt are applied to the ITB. If many scratches are found, replace the ITB. If dirt is applied, clean the ITB. In this case, check the ITB cleaning blade at the same time. 6. Replace the patch sensor unit. • • MEMO: This error also occurs when there is not enough toner in the developing assembly. In this case, check the supplyrelated parts in the developing assembly.
Code: E020-03A0
Description: Toner density sensor (C) output lower limit error. The toner density sensor output (Vsig_ind) is less than 43.
Remedy: 1. Check the connection between the toner density sensor and the DC controller interface PCB. (Connector, Breaking (shorting)) <Y> sensor side: J7133, J8028, J8087 PCB side: J1240, J8085 <M> sensor side: J7134, J8029, J8088 PCB side: J1240, J8085 <C> sensor side: J7135, J8030, J8089 PCB side: J1240, J8086 <Bk> sensor side: J7146, J8015, J8117 PCB side: J1240, J8086 2. Check whether disconnection or shorting of the toner density sensor occurs or not. 3. Replace the developing assembly.
Code: E020-03A2
Description: Toner density sensor (C) output upper limit error. The toner density sensor output (Vsig_ind) is less than 247.
Remedy: 1. Check the connection between the toner density sensor and the DC controller interface PCB. (Connector, Breaking (shorting)) <Y> sensor side: J7133, J8028, J8087 PCB side: J1240, J8085 <M> sensor side: J7134, J8029, J8088 PCB side: J1240, J8085 <C> sensor side: J7135, J8030, J8089 PCB side: J1240, J8086 <Bk> sensor side: J7146, J8015, J8117 PCB side: J1240, J8086 2. Check whether disconnection or shorting of the toner density sensor occurs or not. 3. Replace the developing assembly.