Description: POD deck light air heater high temperature error. A temperature over 120 degreeC was detected for 1 second consecutively
Remedy: 1. Turn OFF and then ON the power. 2. Check or Replace the environment sensor (SR1) 3. Check or Replace the warm air fan (FAN1) 4. Check or Replace the cool air fan (FAN2) 5. Check or Replace the additional fan (FAN3) 6. Check or Replace the air heater (H1) 7. Check or Replace the deck controller PCB (UN1)
Description: POD deck light air heater low temperature error. The heater is not placed in the Ready status even when a specified time has elapsed.
Remedy: 1. Turn OFF and then ON the power. 2. Check or Replace the environment sensor (SR1) 3. Check or Replace the warm air fan (FAN1) 4. Check or Replace the cool air fan (FAN2) 5. Check or Replace the additional fan (FAN3) 6. Check or Replace the air heater (H1) 7. Check or Replace the deck controller PCB (UN1)
Description: High temperature error at the air heater for the upper multi-cassette deck. A high-temperature error was detected at the upper multicassette deck.
Remedy: Failure of the air heater unit (HT101). Failure of the air heater PCB harness. Failure of the upper deck air heater PCB. Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.
Description: High temperature error at the air heater for the middle multi-cassette deck. A high-temperature error was detected at the middle multi-cassette deck.
Remedy: Failure of the air heater unit (HT201). Failure of the air heater PCB harness. Failure of the middle deck air heater PCB. Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.
Description: High temperature error at the air heater for the lower multi-cassette deck. A high-temperature error was detected at the lower multicassette deck.
Remedy: Failure of the air heater unit (HT301). Failure of the air heater PCB harness. Failure of the lower deck air heater PCB. Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.
Description: Low temperature error at the air heater for the upper multi-cassette deck. A low-temperature error was detected at the upper multicassette deck.
Remedy: Failure of the air heater unit (HT101). Failure of the air heater PCB harness. Failure of the upper deck air heater PCB. Failure of the AC distribution PCB (F6). Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.
Description: Low temperature error at the air heater for the middle multi-cassette deck. A low-temperature error was detected at the middle multicassette deck.
Remedy: Failure of the air heater unit (HT201). Failure of the air heater PCB harness. Failure of the middle deck air heater PCB. Failure of the AC distribution PCB (F6). Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.