Các lỗi thường gặp

Code :
  • Code: E001-0102
  • Description: Abnormal temperature rise of pressure subthermistor 1 (THM3) (circuit failure). Pressure subthermistor 1 (THM3) sensed an abnormal high temperature. (ASIC detection)
  • Remedy: 1. Check the detection temperature of the pressure sub thermistor 1 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure sub thermistor 1 (THM-3) is caught -> replace the pressure stay B. In case that the detection temperature is other than 250 degC B-1. The pressure main thermistor is disconnected, the harness is disconnected, foreign substance is gotten in, or failure -> replace the main thermistor or pressure stay B-2. Replace the DC controller PCB
  • Code: E001-0103
  • Description: Abnormal temperature rise of pressure subthermistor 2 (THM4) (circuit failure). Pressure subthermistor 2 (THM4) sensed an abnormal high temperature. (ASIC detection)
  • Remedy: 1. Check the detection temperature of the pressure sub thermistor 2 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure sub thermistor 2 (THM-4) is caught -> replace the pressure stay B. In case that the detection temperature is other than 250 degC B-1. The pressure main thermistor is disconnected, the harness is disconnected, foreign substance is gotten in, or failure -> replace the main thermistor or pressure stay B-2. Replace the DC controller PCB
  • Code: E001-0111
  • Description: Pressure main thermistor abnormal temperature rise (circuit abnormality). Pressure main thermistor (THM2) detected abnormal high temperature. (software detection)
  • Remedy: 1. Check the detection temperature of the pressure main thermistor in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure main thermistor (THM-2) is caught -> replace the thermistor or the pressure stay B. In case that the detection temperature is other than 250 degC B-1. Replace the DC controller PCB
  • Code: E001-0112
  • Description: Pressure sub thermistor 1(THM3)abnormal temperature rise (circuit abnormality). Pressure sub thermistor 1(THM3) detected abnormal high temperature. (software detection)
  • Remedy: 1. Check the detection temperature of the pressure sub thermistor 1 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure sub thermistor 1 (THM-3) is caught -> replace the pressure stay B. In case that the detection temperature is other than 250 degC B-1. The pressure main thermistor is disconnected, the harness is disconnected, foreign substance is gotten in, or failure -> replace the main thermistor or pressure stay B-2. Replace the DC controller PCB
  • Code: E001-0113
  • Description: Pressure sub thermistor 2 (front) abnormal temperature rise (circuit abnormality). Pressure sub thermistor 2(THM4) detected abnormal high temperature. (software detection)
  • Remedy: 1. Check the detection temperature of the pressure sub thermistor 2 in service mode. A. In case that the detection temperature is 250 degC A-1. The cable of the pressure sub thermistor 2 (THM-4) is caught -> replace the pressure stay B. In case that the detection temperature is other than 250 degC B-1. The pressure main thermistor is disconnected, the harness is disconnected, foreign substance is gotten in, or failure -> replace the main thermistor or pressure stay B-2. Replace the DC controller PCB
  • Code: E002-0002
  • Description: Insufficient fixing belt temperature rise 1. In a warm-up, the temperature of fixing main thermistor (THM1-1) does not reach to 80 degrees Celsius within 120 seconds after reaching to 50 degrees Celsius
  • Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Replace the fixing belt unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer connector is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB
  • Code: E002-0003
  • Description: Insufficient fixing belt temperature rise 2. In a warm-up, the temperature of fixing main thermistor (THM1-1) does not reach to 110 degrees Celsius within 120 seconds after reaching to 80 degrees Celsius.
  • Remedy: 1. Check the detection temperature of the thermistor in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing belt unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing belt unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB
  • Code: E002-0004
  • Description: Insufficient fixing belt temperature rise 3. In a warm-up, the temperature of fixing main thermistor (THM1-1) does not reach to 130 degrees Celsius within 120 seconds after reaching to 110 degrees Celsius.
  • Remedy: 1. Check the detection temperature of the thermistor in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing belt unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing belt unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing belt unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB