Description: Hard disk failure. /IMG_MNG is abnormal
Remedy: 1. Input applicable CHK-TYPE into a partition; and execute HDD-CHECK (requires several minutes to some dozens of minutes); and then power cycle 2. If not recovery, input applicable CHK-TYPE into a partition; and execute HDD-CLEAR; and then power cycle
Description: Hard disk failure. /IMG_MNG is abnormal
Remedy: 1. Check a cable or power supply connector 2. If not recovery, Boot-up in safe mode, and use SST to execute full-format and to re-install system (SYSTEM, LANGUAGE, RUI); and then power cycle of main power (Power OFF/ON) 3. If still not recovery, replace HDD and re-install system based on judging HDD failure.
Description: Hard disk failure. /IMG_MNG is abnormal
Remedy: 1. input applicable CHK-TYPE into a partition; and execute HDD-CLEAR; and then power cycle 2. If not recovery, replace HDD and re-install system based on judging HDD failure.
Description: Hard disk failure. /IMG_MNG is abnormal
Remedy: This is an error due to data error or software bug. 1. Boot-up in safe mode, and use SST to execute fullformat and to re-install system (SYSTEM, LANGUAGE, RUI); and then power cycle of main power (Power OFF/ON) 2. If not recovery, replace HDD and re-install system based on judging HDD failure.
Description: Hard disk failure. /IMG_MNG is abnormal
Remedy: This is an error that usually does not occur at Read/Write level. 1. Check a cable or power supply connector 2. If not recovery, replace HDD and re-install system based on judging HDD failure.
Description: Re-reboot due to failures such as SRAM damage when executing the power shutdown safeguard transmission job. SRAM data is damaged and stored job data cannot be read. If this causes the repeated reboot execution after recovery from power shutdown, a transmission is also repeated. Therefore "E code" is displayed.
Remedy: Execute SRAM clear and delete power shutdown safeguard job