Description: The temperature of the fixing assembly is abnormally high.
When the main power switch is turned on, the reading of the main thermistor does not reach 70 deg C within 3 min 30 sec.
Remedy: - Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Description: The over-rising in temperature of the fixing assembly is detected.
Either the main thermistor or the sub thermistor detects 230 deg C or higher for 2 sec.
Remedy: - Check if the main thermistor and the sub thermistor are mounted properly. - Replace the main thermistor or the sub thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Description: The over-rising in temperature of the fixing assembly is detected.
The reading of the main thermistor is higher than that of the sub thermistor by 50 deg C or more for 1 sec.
Remedy: Check if the main thermistor and the sub thermistor are mounted properly. - Replace the main thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Description: The over-rising in temperature of the fixing assembly is detected.
The reading of the main thermistor is lower than that of the sub thermistor by 50 deg C or more for 1 sec.
Remedy: - Check if the main thermistor is mounted properly. - Replace the main thermistor. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Description: The rise in temperature of the fixing assembly is faulty.
The reading of the main thermistor (TH1) does not reach 100 deg C 2 min 30 sec after it has exceeded 70 deg C.
Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.