Code :
  • Code: E002-0001
  • Description: The rise in temperature of the fixing assembly is faulty.
    The reading of the main thermistor does not reach 150 deg C within 2 min 30 sec after it has exceeded 100 deg C.
  • Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E002-0010
  • Description: The rise in temperature of the fixing assembly is faulty.
    The power has been turned off and then on without clearing the error.
  • Remedy: - Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E003-0000
  • Description: The fixing temperature is too low after a standby state.
    The reading of the main thermistor is 70 deg C or lower for 2 sec or more after it has reached 100 deg C.
  • Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E003-0010
  • Description: The fixing temperature is too low after a standby state.
    The power has been turned off and then on without clearing the error.
  • Remedy: - Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E004-0000
  • Description: The fixing assembly is faulty.
    The SSR used to drive the fixing heater has a short circuit (detection by hardware circuitry).
  • Remedy: - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You will have to clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E005-0000
  • Description: The absence of the fixing web is detected.
    The length of the fixing web that has been taken up is more than a specific value and the fixing web length sensor (PS7) has detected the absence of the web for 5 sec or more.
  • Remedy: - Check the position of the fixing web detection lever. - Replace the fixing web. - Replace the fixing web length sensor. - Replace the DC controller PCB. Caution After replacing the fixing web, you will have to clear the two web counters in service mode (COPIER>COUNTER>MISC>FIX-WEB and COPIER>COUNTER>DRBL-1>FIX-WEB).
  • Code: E005-0010
  • Description: The absence of the fixing web is detected.
    The power is turned off and then on without clearing the error.
  • Remedy: - Reset the counters of the two webs to zero in service mode (COPIER>COUNTER>MISC>FIX-WEB, COPIER>COUNTER>DRBL-1>FIX-WEB)
  • Code: E010-0000
  • Description: The rotation of the main motor is faulty.
    No clock pulse arrive for 2 sec or more after the main motor drive signal (MMFG) has been generated.
  • Remedy: - Check if the connecter (J611, J612) of the main motor is mounted properly. - Check if the connector (J1720) of the relay PCB is mounted properly. - Replace the main motor. - Replace the relay PCB. - Replace the DC controller PCB.