Description: There is a coin vendor error.
While the unit price is being checked at startup, an error occurs in the communication with the coin vendor.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Code: E719-0011
Description: There is a coin vendor error.
An error has occurred at new card reader startup. The new card reader is not connected when the power is turned off, although it was connected when the power was turned off.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Code: E719-0012
Description: There is a coin vendor error.
An IPC error has occurred at new card reader startup. There is an IPC open circuit. An error has occurred that prevents recovery of IPC communication.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR>ERR.
Code: E730-1001
Description: There is a PDL software error.
An initialization error has occurred.
Remedy: - Execute PDL resetting. - Turn on the power once again.
Code: E730-100A
Description: There is a PDL software error.
An error that may be critical to the system (e.g., failed initialization) has occurred.
Remedy: - Execute PDL resetting. - Turn on the power once again.
Code: E730-9004
Description: There is a PDL software error.
There is an error in the communication (PAI) with an external controller.
Remedy: - Turn on the power once main. - Check the connection of the open I/F board and the cable. - Replace the board for the external controller open I/F. - Replace the main controller PCB.
Code: E730-9005
Description: There is a PDL software error.
Fault in the connector of the vide cable to the external controller
Remedy: - Turn on the power once main. - Check the connection of the open I/F board and the cable. - Replace the board for the external controller open I/F. - Replace the main controller PCB.
Code: E730-A006
Description: There is a PDL software error.
The PDL board does not respond. A subbootable is faulty or absent.
Remedy: - Execute PDL resetting. - Turn on the power once again. - Check the connection of the UFR board. - Re-install the firmware. - Replace the main controller PCB.