Các lỗi thường gặp

Code :
  • Code: E000-0001
  • Description: Fixing temperature rising error
    The detected temperature of the Main Thermistor failed to reach the specified temperature at temperature rising control.
  • Remedy: 1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power. 2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB) 3. Replace the Fixing Assembly. 4. Replace the DC Controller PCB (PCB1).
  • Code: E001-0000
  • Description: Detection of overheating of Fixing Assembly
    The Main Thermistor detected 250 deg C or higher for 200 msec or longer on end.
  • Remedy: 1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power. 2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB) 3. Replace the Fixing Assembly. 4. Replace the DC Controller PCB (PCB1).
  • Code: E001-0001
  • Description: Detection of overheating of Fixing Assembly
    The hardware circuit detected overheating of the Main Thermistor or Sub Thermistor for 30 msec or longer.
  • Remedy: 1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power. 2. Replace the DC Controller PCB (PCB1).
  • Code: E001-0002
  • Description: Detection of overheating of Fixing Assembly
    The Sub Thermistor detected 295 deg C or higher for 200msec or longer on end.
  • Remedy: 1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power. 2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB) 3. Replace the Fixing Assembly. 4. Replace the DC Controller PCB (PCB1).
  • Code: E002-0000
  • Description: Error in temperature rising of Fixing Assembly
    1. The Main Thermistor detected a temperature lower than 115 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 100 deg C.
    2. The Main Thermistor detected a temperature lower than 150 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 140 deg C.
  • Remedy: 1. The Main Thermistor detected a temperature lower than 115 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 100 deg C. 2. The Main Thermistor detected a temperature lower than 150 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 140 deg C.
  • Code: E003-0000
  • Description: Detection of fixing low temperature during printing
    The Main Thermistor detected a temperature lower than 80 deg C for 200 msec or longer on end, or the Sub Thermistor detected a temperature lower than 60 deg C for 200 msec or longer on end.
  • Remedy: 1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power. 2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB) 3. Replace the Fixing Assembly. 4. Replace the DC Controller PCB (PCB1).
  • Code: E004-0000
  • Description: Thermistor disconnection detection error
    Connector disconnection was detected for 30 msec on end.
  • Remedy: 1. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB) 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB (PCB1).
  • Code: E010-0001
  • Description: Main Motor (M2) rotation error
    Detection was performed every 100 msec since the start of drive and there had been no lock detection signal in 2 seconds.
  • Remedy: 1. Check the connector between the Main Motor and the DC Controller PCB (J203). 2. Replace the Main Motor (M2). 3. Replace the DC Controller PCB (PCB1).
 1 2 3 4 >  Last ›