Description: Tray Auxiliary Guide Motor (M6) error
The Tray Auxiliary Guide Motor (M6) was driven for 1.8 seconds, but the Tray Auxiliary Guide could not be detected by the Tray Auxiliary Guide HP Sensor (S6).
Remedy: 1. Check the connector connection of the Tray Auxiliary Guide HP Sensor (S6) or the Tray Auxiliary Guide Motor (M6). 2. Check for open circuit of the Harness of the Tray Auxiliary Guide HP Sensor (S6) or the Tray Auxiliary Guide Motor (M6). 3. Replace the Tray Auxiliary Guide HP Sensor (S6). 4. Replace the Tray Auxiliary Guide Motor (M6). 5. Replace the Finisher Controller PCB.
Code: E719-0000
Description: Error in communication with the Copy Card Reader-F1 (serial communication)
Card Reader was not connected at department management setting.
Remedy: 1. Check the connection with the Card Reader. 2. Remove the Card Reader, and execute the following: service mode > #CLEAR > ERR > E719.
Code: E736-0000
Description: Fax Board mismatch error
Combination of the Fax Board type and the country was mismatched
Remedy: This error occurred in the following cases. - Fax Board for non-Chinese models was installed to a Chinese model. - Fax Board for Chinese models was installed to a non-Chinese model. - For Chinese models, replace the Fax Board with that for Chinese models. - For non-Chinese models, replace the Fax Board with that for non- Chinese models
Code: E804-0000
Description: Power Supply Cooling Fan (FM4) error
A lock signal was detected for 5 seconds while the Power Supply Cooling Fan (FM4) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Disconnect and then connect the connector (J209) on the DC Controller PCB (PCB1) to check the connection. 2. Replace the Power Supply Cooling Fan (FM4). 3. Replace the DC Controller PCB (PCB1).
Code: E804-0001
Description: Error in rotation of the Power Supply Cooling Fan (FM4)
A lock signal could not be detected for 5 seconds while the Power Supply Cooling Fan (FM4) was being driven. *The same status was detected again after executing an error retry.
Remedy: 1. Disconnect and then connect the connector (J209) on the DC Controller PCB (PCB1) to check the connection. 2. Replace the Power Supply Cooling Fan (FM4). 3. Replace the DC Controller PCB (PCB1).
Code: E805-0000
Description: Heat Exhaust Fan (Rear) (FM6) error
A lock signal was detected for 5 seconds while the Heat Exhaust Fan (Rear) (FM6) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Disconnect and then connect the connector (J212) on the DC Controller PCB (PCB1) to check the connection. 2. Replace the Heat Exhaust Fan (Rear) (FM6). 3. Replace the DC Controller PCB (PCB1).
Code: E805-0001
Description: Error in rotation of the Heat Exhaust Fan (Rear) (FM6)
A lock signal could not be detected for 5 seconds while the Heat Exhaust Fan (Rear) (FM6) was being driven. *The same status was detected again after executing an error retry.
Remedy: 1. Disconnect and then connect the connector (J212) on the DC Controller PCB (PCB1) to check the connection. 2. Replace the Heat Exhaust Fan (Rear) (FM6). 3. Replace the DC Controller PCB (PCB1).
Code: E805-0002
Description: Heat Exhaust Fan (Front) (FM5) error
A lock signal was detected for 5 seconds while the Heat Exhaust Fan (Front) (FM5) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Disconnect and then connect the connector (J212) on the DC Controller PCB (PCB1) to check the connection. 2. Replace the Heat Exhaust Fan (Front) (FM5). 3. Replace the DC Controller PCB (PCB1).