Các lỗi thường gặp

Code :
  • Code: E000-0001
  • Description: Fixing temperature abnormal rise
    The temperature detected by the main thermistor does not rise to the specified value during startup control.
  • Remedy: 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn OFF and then ON the power. 2.Check connection of the Connectors (Thermistor Connector and AC Connector). 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4).
  • Code: E001-0000
  • Description: Fixing unit temperature rise detection
    The reading of the main thermistor is 250 deg C or more continuously for 200 msec.
  • Remedy: 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn OFF and then ON the power. 2.Check connection of the Connectors (Thermistor Connector and AC Connector). 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4).
  • Code: E001-0001
  • Description: Fixing unit temperature rise detection
    The hardware circuit detects overheating of the main or sub thermistor for 200 msec.
  • Remedy: 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn OFF and then ON the power. 2.Replace the DC Controller PCB (PCB4).
  • Code: E001-0002
  • Description: Fixing unit temperature rise detection
    The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.
  • Remedy: 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn OFF and then ON the power. 2.Check connection of the Connectors (Thermistor Connector and AC Connector). 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4).
  • Code: E002-0000
  • Description: Fixing unit temperature insufficient rise
    1.The reading of the main thermistor is less than 115 deg C continuously for 400 msec 1.3 sec after it has indicated 100 deg C.
    2.The reading of the main thermistor is less than 150 deg C continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
  • Remedy: 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn OFF and then ON the power. 2.Check connection of the Connectors (Thermistor Connector and AC Connector). 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4).
  • Code: E003-0000
  • Description: Low fixing temperature detection after standby
    The reading of the main thermistor is less than 140 deg C continuously for 400 msec or more.
  • Remedy: 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn OFF and then ON the power. 2.Check connection of the Connectors (Thermistor Connector and AC Connector). 3.Replace the Fixing Main Thermistor (Film Unit). 4.Replace the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4).
  • Code: E004-0000
  • Description: Thermistor disconnection detection error
    When disconnection is detected with connector (J214) for 30 sec continuously.
  • Remedy: 1.Check connection of the Connector (J214). 2.Replace the Film Unit. 3.Replace the Fixing Assembly. 4.Replace the DC Controller PCB (PCB4).
  • Code: E010-0001
  • Description: Unstable rotation of the Main Motor (M1)
    Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
  • Remedy: 1.Replace the Main Motor (M1). 2.Replace the DC Controller PCB (PCB4).
 1 2 3 4 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục