Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR2535 — Trang 7/9

Code: E575-0001

Description: Gripper Unit Move Motor (M2) error
The gripper unit does not leave the gripper unit home position when the Gripper Unit Move Motor (M2) has been driven for 3.8 seconds.
Remedy: 1.Replace the Gripper Unit HP Sensor (S7). 2.Replace the Gripper Unit Move Motor (M2). 3.Replace the Finisher Controller PCB (PCB1).

Code: E575-0002

Description: Gripper Unit Move Motor (M2) error
The gripper unit does not return to the gripper unit home position when the Gripper Unit Move Motor (M2) has been driven for 0.1 seconds.
Remedy: 1.Replace the Gripper Unit HP Sensor (S7). 2.Replace the Gripper Unit Move Motor (M2). 3.Replace the Finisher Controller PCB (PCB1).

Code: E602-0001

Description: The built-in SD card is not detected
Remedy:

Code: E602-1105

Description: Access to the built-in SD card failed
Remedy:

Code: E711-0001

Description: Error in UFDI communication
The communication system error (such as reception timeout or checksum error) occurred.
Remedy: 1.Check and Replace the cable. 2.Replace the DC Controller PCB (PCB4). 3.Replace the Finisher Controller PCB.

Code: E713-0000

Description: Erroneous communication with finisher
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1.Check the cable. 2.Replace the DC Controller PCB (PCB4). 3.Replace the Finisher Controller PCB.

Code: E716-0000

Description: Erroneous communication with optional cassette or 2-way unit
After the presence of a cassette pedestal or a 2-way unit has been detected, the communication fails to be normal for 5 sec.
Remedy: 1.Check the cable. 2.Replace the DC Controller PCB (PCB4). 3.Replace the Cassette Pedestal Driver PCB. 4.Replace the 2-way unit driver PCB.

Code: E716-0010

Description: Failure of the communication with the 2-way unit
When the communication with the 2-way unit is faulty after detecting the connection with the finisher.
Remedy: 1.Install the 2-way unit. 2.Check the cable. 3.Replace the DC Controller PCB (PCB4). 4.Replace the 2-way unit driver PCB.