Description: Failure in PS Printer Kit-AA1
Abnormal detection with configuration check when PS Printer Kit-AA1 is started
Remedy: - Check cable connection - Reinstall system of PS Printer Kit-AA1
Code: E677-0004
Description: Failure in PS Printer Kit-AA1
Failure in CPU cooling fan of PS Printer Kit-AA1
Remedy: - Check connection of the connector for cooling CPU - Replace CPU cooling fan
Code: E677-0010
Description: Failure in PS Printer Kit-AA1
In the case that other type of controller is connected
Remedy: - Check connection of controller that supports this machine
Code: E677-0080
Description: Failure in PS Printer Kit-AA1
Communication error between PS Printer Kit-AA1 and the main controller of the host machine after PS Printer Kit-AA1 is started
Remedy: - After checking connection, turn ON the power again. - Reinstall system of PS Printer Kit-AA1.
Code: E710-0001
Description: There is an error in the initialization of the IPC.
The machine fails to become ready 3 sec or less after the IPC chip startup
Remedy: Check the cable.
Code: E711-0001
Description: There is an error in the IPC communication.
The occurrence of an error has been recorded in the error register of the IPC chip 4 times or more within 1.5 sec.
Remedy: Check the cable.
Code: E713-0000
Description: There is an error in the communication with the finisher or 3 Way Unit-A1.
The communication with the finisher does not resume within 5 sec after it has been disrupted.
Remedy: Check the cable. Replace the DC controller PCB. Replace the finisher controller PCB.
Code: E716-0000
Description: There is an error in the communication with the pedestal.
After the presence of a pedestal has been detected, the communication fails to be normal for 5 sec.
Remedy: Check the cable. Replace the DC controller PCB. Replace the pedestal drive PCB.