Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The IH input voltage is too high.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The IH input voltage is too low.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
At power-on (or, when IH is at reset), the IH control mechanism is not in an initial state.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
At IH start-up, the IH control enable flag is not set within 1 sec after the start flag is set.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
With IH at rest, the IH control flag is not released.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The 12-V power supply (IH relay) is identified as being off.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
At IH start-up, the PWM/ON data is faulty ('0' or 'FFFF')
Description: There is no fixing web/there is an error in the detection of web solenoid connection.
The absence of the fixing web has been detected for 5 sec or more.
Remedy: - Replace the fixing web. - Replace the fixing web length sensor. - Replace the DC controller PCB. After correcting the fault, be sure to reset the fixing web counter reading. (COPIER>COUNTER>MISC>FIX-WEB)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.