Description: The high-voltage output has a fault.
A fault is detected at the same time in 2 of the following: primary high voltage, pre-transfer high voltage, transfer high voltage, separation high voltage.
Remedy: Remove and mount the primary charging assembly. Remove and mount the pre-transfer charging assembly. Remove and mount the transfer/ separation charging assembly. Disconnect and then connect J721, J723, J731, and J734 of the HV-DC PCB. Replace the HV-DC PCB. Replace the HV-AC PCB.
Code: E068-0000
Description: The high-voltage output has a fault. (separation charging assembly)
A fault (leak) has been detected while the separation charging assembly is being supplied with high voltage.
Remedy: Remove and mount the transfer/separation charging assembly. Disconnect and then connect J7233 and J734 of the HV-DC PCB. Disconnect and then connect J741 and J742 of the HV-AC PCB. Replace the HV-AC PCB. Replace the transfer/ separation charging assembly. Replace the pre-transfer charging assembly.
Code: E069-0000
Description: The transfer high voltage has an error.
A fault (leak) has been detected while the transfer charging assembly is being supplied with high voltage.
Remedy: Remove and mount the transfer/separation charging assembly. Check for soiling. Disconnect and then connect T701 and J723 of the HV-DC PCB. Replace the HV-DC PCB. Replace the pre-transfer charging assembly.
Code: E102-0001
Description: A read error has occurred in relation to the laser scanner unit EEPROM data.
The correction data cannot be read from the EEPROM of the laser scanner unit.
Remedy: Disconnect and then connect the connector of the video PCB. Disconnect and then connect the DC controller PCB. Replace the laser scanner unit.
Code: E110-0000
Description: The laser scanner motor rotation has a fault.
After the laser scanner motor has gone on, the PLL lock signal of the motor is not detected for 15 sec or more.
Remedy: Check to see if all covers have been attached to the primary charging assembly. Disconnect and then connect J764 of the laser scanner motor drive PCB (in the laser scanner unit). Disconnect and then connect J1401 of the video PCB. Disconnect and then connect J506 of the DC controller PCB. Replace the laser scanner unit. Replace the video PCB. Replace the DC controller PCB.
Code: E111-0000
Description: The laser scanner motor cooling fan rotation has a fault.
After the laser scanner motor cooling fan has gone on, the fan stop signal is detected for 5 sec or more.
Remedy: Disconnect and then connect J503 of the DC controller PCB. Replace the laser scanner motor cooling fan. Replace the DC controller PCB.
Code: E121-0001
Description: A fault exists in the rotation of the following: laser scanner unit cooling fan, reader heat discharge fan 1, reader heat discharge fan 2.
The laser scanner unit cooling fan has a fault. After the laser scanner unit cooling fan has gone on, the fan stop signal is detected for 5 sec or more.
Remedy: Disconnect and then connect J503 of the DC controller PCB. Replace the laser scanner unit cooling fan. Replace the DC controller PCB.
Code: E121-0002
Description: A fault exists in the rotation of the following: laser scanner unit cooling fan, reader heat discharge fan 1, reader heat discharge fan 2.
The reader heat discharge fan 1 has a fault. After the reader heat discharge fan 1 has gone on, the fan stop signal is detected for 5 sec or more.
Remedy: Connect and then disconnect J512 of the DC controller PCB. Replace the reader heat discharge fan 1. Replace the DC controller PCB.