Mã lỗi Epson Stylus Pro 10600 — Trang 2/9

Code: 00000103

Display: SERVICE CALL 00000103 : Waste ink box on the left side full
Description: It is ’00,000,100’ and time in the detailed that displayed it to the LCD panel and be not fatal error.
Remedy: Not necessary ("Waste ink Initialization" of maintenance mode 2 is run.)

Code: 00010000

Display: SERVICE CALL 00010000: PF ENCODER CHECK ERROR
Description: PF motor encoder check error The PF motor makes small revolutions clockwise and counter-clockwise. When it turns, the printer checks the rotary encoder (inside the motor) output signals to make sure the motor is turning at the correct speed/distance. If the encoder sends an incorrect signal, an error occurs.
Remedy: Make sure there is nothing blocking the grid rollers. If that does not solve the problem, check the PF motor encoder connection. If there still is a problem, carry out the tension adjustment or phenol-formaldehyde motor exchange of the phenol-formaldehyde timing belt. If there is not a problem, carry out the following items. • Confirming whether the dirt and dust are not adhering to the PF loop scale and PF encoder. • The cable connector joint of the PF encoder and C362DRV board (CN8) are confirmed. • The PF timing belt tension confirmation/adjustment. In the case that there is not abnormality with above checking I gradually exchange the next part. • PF encoder • PF timing belt • PF loop scale • PF encoder extension cable • C362DRV board

Code: 00010001

Display: SERVICE CALL 00010001: PF MOTOR STEP-OUT
Description: PF motor out of step - the length of the PF motor internal encoder’s pulse is too long or too short compared to the regular pulse.
Remedy: Make sure there is nothing blocking the grid rollers. If that does not solve the problem, check the PF motor encoder connection. If there still is a problem, try the following. • PF timing belt exchange • PF motor exchange • PF motor extension cable exchange • C362DRV board exchange.

Code: 00010002

Display: SERVICE CALL 00010002: PF MOTOR OVER CURRENT
Description: PF motor overcurrent - Feedback from the PF motor (IC35) driver’s 10-pin output (sensor signal) indicates that the PF motor’s current is irregular.
Remedy: • The coil resistance value (6.7Ohm) the measurement of the PF motor. • PF motor extension cable exchange. • C362DRV board exchange.

Code: 00010003

Display: SERVICE CALL 00010003: PF MOTOR IN POSITION TIME OUT
Description: When be it locateds stable at the time of halt processing with the PF motor control, (the in position time) the position control inside period did not improve.
Remedy: • PF motor exchange • PF encoder exchange • PF timing belt exchange • C362DRV board exchange

Code: 00010004

Display: SERVICE CALL 00010004: CR ENCODER CHECKING ERROR
Description: CR motor encoder check error The CR motor makes small revolutions clockwise and counter-clockwise.When it turns, the printer checks the encoder output signals to make sure the motor is turning at the correct speed/distance. If the encoder doesn’t send the correct signal or output data, an error occurs.
Remedy: It confirms whether there is not abnormal load etc. at the time of carriage migration and be abnormal no and do the checking of the CR encoder, in the case that the error is not canceled. In the case that there is abnormality : Carry out the tension of the steel belt adjustment or CR motor exchange. In the case that there is not abnormality : Confirm whether there are not dirt and damage in the CR encoder. The cable connector joint to the CR encoder and head Assy board CN15 are confirmed. Encoder pulse detection for T fence (scale 180a) of it comes off/whether or not there is not the contact with a CR encoder • Confirmation of the dirt/paper powder/damage of the confirmation T fence (scale 180a) the top • CR encoder exchange • CR motor exchange • C362DRV board exchange

Code: 00010005

Display: SERVICE CALL 00010005: CR MOTOR STEP-OUT
Description: The rotational speed of the CR motor abnormal. (it is long/short period at the time of prescription ).
Remedy: It confirms whether there is not abnormal load etc. at the time of carriage migration and be abnormal no and do the checking of the CR encoder, in the case that the error is not canceled. In the case that there is abnormality: • Encoder pulse detection for T fence (scale 180a) of it comes off/whether or not there is not the contact with a CR encoder • Tension adjustment of the confirmation steel belt • Confirmation of the dirt / paper powder / damage of the T fence (scale 180a) the top • CR encoder exchange • CR motor exchange • C362DRV board exchange

Code: 00010006

Display: SERVICE CALL 00010006: CR MOTOR OVER CURRENT
Description: CR motor overcurrent - Feedback from the CR motor (IC33) driver’s 10-pin output (Sense signal) indicates that the CR motor’s current is irregular.
Remedy: • He resistance value (5.56) the measurement of the n CR motor. In the case that the CR motor exchange motor coil is short condition if there is abnormality exchange.C362DRV board exchange even the C362DRV board • C362DRV board exchange