Các lỗi thường gặp

Code :
  • Code: 1471
  • Description: Pressure motor 1 reverse detection error
    Abnormality of the revolution of the Pressure Motor has been detected.
  • Remedy: Replace the Pressure Pump Unit.
  • Code: 1472
  • Description: Pressure motor 2 reverse detection error
    Abnormality of the revolution of the Pressure Motor has been detected.
  • Remedy: Replace the Pressure Pump Unit.
  • Code: 1473
  • Description: Pressure motor 3 reverse detection error
    Abnormality of the revolution of the Pressure Motor has been detected.
  • Remedy: Replace the Pressure Pump Unit.
  • Code: 150C
  • Description: PG HP detection error
    The home position of the platen gap cannot be detected.
  • Remedy: Check the connection of the PG Sensor. Replace the PG Sensor. Replace the PG Sensor.
  • Code: 1511
  • Description: APG motor drive timeover error
    The motor driving does not end even after the specified period of time has passed.
  • Remedy: Install the latest firmware. Replace the Main Board Assy.
  • Code: 1536
  • Description: Pressurizing reset failure
    The pressurizing cannot be reset. The Pressure Sensor remains on, even after the pressurizing has been reset.
  • Remedy: Replace the Pressure Pump Unit.
  • Code: 16A0
  • Description: Cap unit status error 1
    The position of the Cap Unit is wrong.
  • Remedy: Replace the Ink System Unit (Cap Unit HP Sensor). Replace the Ink System Motor.
  • Code: 16A1
  • Description: Cap unit status error 2
    The position of the Cap Unit is wrong.
  • Remedy: Replace the Ink System Unit (Cap Unit HP Sensor). Replace the Ink System Motor.