Description: CR motor overcurrent
Feedback from the CR motor (IC33) driver’s 10-pin output (Sense signal) indicates that the CR motor’s current is irregular.
Remedy: • Check the CR cover, slightly loosen screws if necessary • Check the cutter housing, slightly loosen screws if necessary • Make sure no foreign material or ink tubes (from pump assembly) are blocking the carriage path (see “Removing the Maintenance Assembly” on page 143 for reassembly points) • Replace the CR motor • Replace the Main Board
Code: 00010007
Description: CR in-position time-out
The in-position time is the amount of time the printer waits to make sure the carriage is not moving when the carriage comes to a stop. The linear encoder is activate for the predetermined “in-position time” and if the encoder sends a pulse, this means the carriage is moving even though it is supposed to be at a full stop, this generates an error.
Remedy: • Replace the encoder sensor • Replace the CR motor • Replace the Main Board
Code: 00010008
Description: Servo interrupt watchdog time-out error
Servo interrupt watchdog time-out error due to motor-drive control related error
Remedy: Replace the Main Board
Code: 00010009
Description: System interrupt watchdog time-out error
System interrupt watchdog time-out error due to sensor-related errorror occurs.
Remedy: Replace the Main Board
Code: 0001000A
Description: CR origin sensor malfunction
CR home position sensor malfunction
Remedy: • Make sure the CR HP sensor is not twisted or bent • Replace the CR HP sensor • Replace the Main Board
Code: 0001000B
Description: PF origin sensor malfunction
PF home position sensor malfunction means motor replacement
Remedy: • Check the PF motor and sensor connections • Replace the PF motor (internal sensor) • Replace the Main Board
Code: 0001000C
Description: PG origin sensor malfunction
(may indicate PG motor malfunction)
Remedy: Make sure there is no ink or dust on the surface of the sensor. If this does not solve the problem, check the PG sensor connection. If there still is a problem, try the following. • Replace the PG sensor • Replace the PG motor • Replace the Main Board
Code: 0001000D
Description: Cover sensor malfunction (00)
Right sensor (HP side) One or both cover open sensors (interlock switch) located at either end of the cover shaft is malfunctioning.
Remedy: Make sure the sensor(s) are properly installed. If that does not solve the problem, check the cover open sensor connection. If there still is a problem, try the following. • Replace the malfunctioning cover sensor • Replace the Main Board