Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Epson SureColor S50610

Code: 1101

Description: Ink Tubes life error
The Ink Tubes have reached the end of their service life. (CR scan pass counter has reached a predetermined limit.)
Remedy: Replace the Ink Tubes and reset the counter .

Code: 1125

Description: CR HP detection error
The CR Unit does not respond to the CR HP Sensor, or the sensor failed to detect the home position. • CR HP Sensor failure • False detection of the home due to paper jam or any other obstacle • Misreading of the CR Scale • CR Lock is damaged.
Remedy: 1. Replace the CR Encoder. 2. Re-install the CR Encoder. If it is faulty, replace it. 3. Clean the CR Scale using ethanol. 4. Replace the CR Scale. 5. Replace the CR Lock .

Code: 1138

Description: CR Motor overcurrent error
1. Connection failure of the CR Motor or the CR Encoder. 2. The number of occurrences of overcurrent to the CR Motor has reached a predetermined limit. • Irregular load • CR Encoder failure • CR Motor failure
Remedy: 1. Replace the CR Encoder. 2. Replace the CR Motor.

Code: 1139

Description: CR Motor oscillation error
The control terminal (Vre terminal) of the CR Motor driver has shorted out.
Remedy: 1. Remove the foreign material. 2. If the error still occurs, replace the Main Board.

Code: 113A

Description: CR Motor overload error
Overcurrent to the CR Motor was detected. • CR Encoder cable is damaged. • CR Motor cable is damaged. • Irregular load • CR Encoder failure • CR Motor failure
Remedy: 1. Re-install the CR Unit. 2. Replace the CR Encoder. 3. Replace the CR Motor.

Code: 113B

Description: CR Motor over speed error
The CR Motor was driven at a speed faster than a predetermined one during deceleration. • Irregular load • CR Encoder failure • SUB Board is damaged. • CR Motor driver failure
Remedy: 1. Replace the CR Encoder. 2. Replace the SUB Board. 3. Replace the Main Board.

Code: 113C

Description: CR Motor reversing error
The number of occurrences of reversing the CR Motor has reached a predetermined limit. • The polarity of CR Encoder cable is opposite. • The polarity of CR Motor cable is opposite. • Slipping of the teeth of CR Timing Belt • CR Encoder failure
Remedy: 1. Adjust the tension of the CR Timing Belt. 2. Replace the CR Encoder.

Code: 113D

Description: CR Motor driving time-out error
Abnormally-long driving duration of the CR Motor was detected. • Irregular load • Firmware becomes out of control
Remedy: Replace the Main Board.