Description: Pressure roller flag detection count error
The pressure roller position sensor could not detect the pressure roller.
Remedy: Correct the height of the pressure roller position sensor. Connect the sensor connector.
Code: 150C
Description: PG position undetectable error
When changing the PG, the PG sensor could not detect the PG position.
Remedy: 1. Replace the PG Sensor. 2. Replace the APG Assy. 3. Remove any obstacles around the CR Unit home position. The printer changes the PG with the CR Unit being at its home position.
Code: 1519
Description: APG Motor oscillation error
The control terminal (Vre terminal) of the APG Motor driver has shorted out.
Remedy: 1. Remove the foreign material. 2. If the error still occurs, replace the Main Board.
Code: 151A
Description: APG Motor overload error
• Connection failure of the APG Motor. • Overcurrent to the APG Motor was detected. • APG Motor cable is damaged. • Irregular load • APG encoder failure • APG Motor failure
Remedy: Replace the APG Motor.
Code: 151B
Description: APG Motor over speed error
The APG Motor was driven at a speed faster than a predetermined one during deceleration. • Irregular load • APG encoder failure • APG Motor driver failure
Remedy: 1. Replace the APG Motor. 2. Replace the Main Board.
Code: 151C
Description: APG Motor reversing error
The number of occurrences of reversing the APG Motor has reached a predetermined limit. • The polarity of APG Motor cable is opposite. • APG Motor failure
Remedy: Replace the APG Motor.
Code: 151D
Description: APG Motor driving time-out error
Abnormally-long driving duration of the APG Motor was detected. • Irregular load • Firmware becomes out of control.
Remedy: Replace the Main Board.
Code: 151E
Description: APG Motor velocity deviation error
The APG Motor was driven at a speed abnormally faster than a predetermined one during acceleration or deceleration. • Irregular load • APG encoder failure • APG Motor failure • APG Motor driver failure
Remedy: 1. Replace the APG Motor. 2. Replace the Main Board.