Các lỗi thường gặp

Code :
  • Code: 141E
  • Description: Pump Motor velocity deviation error
    The Pump Motor was driven at a speed abnormally faster than a predetermined one during acceleration or deceleration. • Irregular load • Pump Motor encoder failure • Pump Motor failure • Pump Motor driver failure
  • Remedy: 1. Replace the Pump Motor encoder and Pump Motor . 2. Replace the Main Board.
  • Code: 141F
  • Description: Pump Motor lock error
    The PF Motor was driven at a speed abnormally slower than a predetermined one during operation. • Irregular load • Pump Motor encoder failure • Pump Motor failure
  • Remedy: Replace the Pump Motor encoder and Pump Motor .
  • Code: 1429
  • Description: Circulation pump motor oscillation error
    The control terminal (Vre terminal) for the circulation pump motor driver is short-circuited.
  • Remedy: 1. Remove the foreign object. 2. Replace the Main Board.
  • Code: 142A
  • Description: Circulation pump motor overload error
    Overcurrent to the circulation pump motor was detected. • Disconnection of the circulation pump motor cable. • Overload • Failure of the circulation pump motor encoder • Failure of the circulation pump motor
  • Remedy: Replace the Circulation Pump Unit.
  • Code: 142B
  • Description: Circulation pump motor overspeed error
    When the circulation pump motor should slow down, it was driving faster than a predetermined speed. • Overload • Failure of the circulation pump motor encoder • Failure of the circulation pump motor driver
  • Remedy: 1. Replace the Circulation Pump Unit. 2. Replace the Main Board.
  • Code: 142C
  • Description: Circulation pump motor reversing error
    The number of detections of reverse driving of the circulation pump motor has reached a predetermined limit. • Incorrect connection of the circulation pump motor cable • Failure of the circulation pump motor
  • Remedy: Replace the Circulation Pump Unit.
  • Code: 142D
  • Description: Circulation pump motor driving time-out error
    The circulation pump motor was driving for an abnormally long time. • Overload • Firmware runaway
  • Remedy: Replace the Main Board.
  • Code: 142E
  • Description: Circulation pump motor velocity deviation error
    When the circulation pump motor should speed up or slow down, it was driving at an abnormally high speed exceeding a predetermined velocity. • Overload • Failure of the circulation pump motor encoder • Failure of the circulation pump motor • Failure of the circulation pump motor driver
  • Remedy: 1. Replace the Circulation Pump Unit. 2. Replace the Main Board.