Description: Roll Unit undetectable error
The Roll Unit could not be detected during mechanism initialization process.
Remedy: Connect the connector of the Roll Unit.
Code: 1612
Description: Roll Unit undetectable error at the start of operation
When the ATC Motor started to operate, it was detected that the Roll Unit status is different from that detected during mechanism initialization process.
Remedy: 1. Connect the connector of the Roll Unit. 2. Turn the printer off and back on.
Code: 1613
Description: Roll Unit undetectable error during operation
The connector of the Roll Unit was disconnected during the ATC Motor was operating.
Remedy: Connect the connector of the Roll Unit.
Code: 1614
Description: Reel Unit undetectable error at the start of operation
When the Reel Motor started to operate, it was detected that the Reel Unit status is different from that detected during mechanism initialization process.
Remedy: 1. Connect the connector of the Reel Unit. 2. Turn the printer off and back on.
Code: 1615
Description: Reel Unit undetectable error during operation
The connector of the Reel Unit was disconnected during the Reel Motor was operating.
Remedy: Connect the connector of the Reel Unit.
Code: 1616
Description: Roll Unit Board failure
There is a problem with a specific bit on the board, which detects what device is connected to the board.
Remedy: Replace the Sub-F Board of the Roll Unit.
Code: 1617
Description: Reel Unit Board failure
There is a problem with a specific bit on the board, which detects what device is connected to the board.
Remedy: Replace the Sub-F Board of the Reel Unit.
Code: 1618
Description: Roll/Reel Unit Board failure
There is a problem with a specific bit on the board, which detects what device is connected to the board.
Remedy: Replace the Sub-F Board of the Roll Unit and Reel Unit .