Các lỗi thường gặp

Code :
  • Code: 159C
  • Description: Reversing error
    The number of occurrences of reversing the ATC Motor has reached a predetermined limit. • The polarity of ATC MOTOR cable is opposite. • ATC MOTOR failure
  • Remedy: Replace the ATC MOTOR.
  • Code: 159D
  • Description: Driving time-out error
    Abnormally-long driving duration of the ATC MOTOR was detected. • Irregular load • Firmware becomes out of control.
  • Remedy: Replace the MAIN BOARD.
  • Code: 159E
  • Description: Velocity deviation error
    The ATC MOTOR was driven at a speed abnormally faster than a predetermined one during acceleration or deceleration. • Irregular load • ATC MOTOR encoder failure • ATC MOTOR failure • ATC MOTOR driver failure
  • Remedy: 1. Replace the ATC MOTOR. 2. Replace the MAIN BOARD.
  • Code: 159F
  • Description: Lock error
    Connection failure of the ATC MOTOR. • The ATC MOTOR was driven at a speed abnormally slower than a predetermined one during operation. • Irregular load • ATC MOTOR encoder failure • ATC MOTOR failure
  • Remedy: Replace the ATC MOTOR.
  • Code: 1620
  • Description: Pressurizing initialization error
    The initialization process did not complete within a predetermined time period.
  • Remedy: 1. Replace the pressure unit (IC HOLDER). 2. If the error still occurs, replace the MAIN BOARD.
  • Code: 1621
  • Description: Pressurizing/Suction switching error
    The pressurizing and suction processes did not complete within a predetermined time period.
  • Remedy: 1. Replace the pressure unit (IC HOLDER). 2. If the error still occurs, replace the MAIN BOARD.
  • Code: 1622
  • Description: Operating time-out error
    The switching operation did not complete within a predetermined time period.
  • Remedy: 1. Replace the pressure unit (IC HOLDER). 2. If the error still occurs, replace the MAIN BOARD.
  • Code: 1623
  • Description: Continuous revolution error
    The control terminal (Vre terminal) of the pressure motor driver has shorted out.
  • Remedy: 1. Remove the foreign materials. 2. If the error still occurs, replace the MAIN BOARD.
‹ First  < 6 7 8 9 10 11 12 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục