Description: The yellow-image-drum motor experienced a rotational error.
Remedy: 1. Perform the image-drum motors component test in the Troubleshooting menu. 2. Reconnect the connectors of the yellowimage- drum motor (J1712) and the DC controller PCA (J138). 3. Replace the yellow-image-drum motor.
Description: The developer-disengagement motor experienced a rotational error.
Remedy: 1. Perform the alienation motor component tests in the Troubleshooting menu. 2. Reconnect the connectors of the yellow/ magenta-developing disengagement motor (J1719), cyan/black-developing disengagement motor (J1718), print cartridge PCA (J404, J405, J406, J408), and the DC controller PCA (J141, J142). 3. Check the print-cartridge drive unit if the adjustment pin sticks in. 4. Check the main drive unit if the lever locks. 5. Replace the primary-transfer-roller disengagement motor.
Description: The primary-transfer-roller disengagement motor experienced an error.
Remedy: 1. Check the ITB alienation sensor (m) by performing either the manual sensor test or the paper-path sensors test in the Troubleshooting menu. 2. Reconnect the connectors of the ITB home-position sensor (J2010), the cartridge driver PCA (J406, J407), and the DC controller PCA (J142). 3. Perform the ITB contact/alienation component test in the Troubleshooting menu. 4. Reconnect the connectors of the primary-transfer-roller disengagement motor (J1709) and the DC controller PCA (J110). 5. Replace the primary-transfer-roller disengagement motor.
Description: The Tray 2 lifter motor experienced an error.
Remedy: 1. Check the Tray-2 paper-surface sensor in the Manual Sensor Test 2 menu in the Troubleshooting menu. 2. Reconnect the connectors of the cassette lifter motor (J1920) and the DC controller PCA (J112). 3. Replace the lifter drive unit.
Description: The Tray 3 lifter motor experienced an error
Remedy: 1. Check the Tray-3 paper-surface sensor in the Manual Sensor Test 2 menu in the Troubleshooting menu. 2. Reconnect the connectors of the cassette lifter motor (J1920) and the DC controller PCA (J112). 3. Replace the lifter drive unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.