Description: The fuser motor has experienced a rotational error
Remedy: 1. Perform the fuser motor component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the fixing motor (J1711), intermediate (J1720) and the DC controller PCA (J105). 3. Replace the fuser motor.
Description: The black-image-drum motor has experienced a startup error.
Remedy: 1. Perform the image-drum-motors component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the blackimage- drum motor (J1715) and the DC controller PCA (J139). 3. Replace the black-image-drum motor.
Description: The cyan-image-drum motor has experienced a startup error.
Remedy: 1. Perform the image-drum-motors component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the cyanimage- drum motor (J1714) and the DC controller PCA (J139). 3. Replace the cyan-image-drum motor.
Description: The magenta-image-drum motor has experienced a startup error.
Remedy: 1. Perform the image-drum-motors component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the magenta-image-drum motor (J1713) and the DC controller PCA (J138). 3. Replace the magenta-image-drum
Description: The yellow-image-drum motor has experienced a startup error.
Remedy: 1. Perform the image-drum-motors component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the yellowimage- drum motor (J1712) and the DC controller PCA (J138). 3. Replace the yellow-image-drum motor.
Description: The black-image-drum motor has experienced a rotational error.
Remedy: 1. Perform the image-drum-motors component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the blackimage- drum motor (J1715) and the DC controller PCA (J139). 3. Replace the black-image-drum motor.
Description: The cyan-image-drum motor has experienced a rotational error.
Remedy: 1. Perform the image-drum-motors component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the cyanimage- drum motor (J1714) and the DC controller PCA (J139). 3. Replace the cyan-image-drum motor.
Description: The magenta-image-drum motor has experienced a rotational error.
Remedy: 1. Perform the image-drum-motors component test in the DIAGNOSTICS menu. 2. Reconnect the connectors of the magenta-image-drum motor (J1713) and the DC controller PCA (J138). 3. Replace the magenta-image-drum motor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.