Display: 59.0X.50 Error To continue turn off then on
Description: Motor startup error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
CMY drum motor (M2) start up error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.07.60
Display: 59.0X.60 Error To continue turn off then on
Description: Motor rotational error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
Remedy: CMY drum motor (M2) rotation error 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.07.70
Display: 59.0X.70 Error To continue turn off then on
Description: Motor abnormal rotation
CMY developer motor (M3) abnormal start up error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Code: 59.07.80
Display: 59.0X.80 Error To continue turn off then on
Description: Developer motor failure
CMY developer motor (M3) failure error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Code: 59.08.50
Display: 59.0X.50 Error To continue turn off then on
Description: Motor startup error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
CMY drum motor (M2) start up error
Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.08.60
Display: 59.0X.60 Error To continue turn off then on
Description: Motor rotational error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
Remedy: CMY drum motor (M2) rotation error 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
Code: 59.08.70
Display: 59.0X.70 Error To continue turn off then on
Description: Motor abnormal rotation
CMY developer motor (M3) abnormal start up error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
Code: 59.08.80
Display: 59.0X.80 Error To continue turn off then on
Description: Developer motor failure
CMY developer motor (M3) failure error
Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.