Remedy: • Check that the cable from the Ink Supply Station (ISS) PCA to the Ink Supply Station is correctly connected.• Check that the Air Pressurization System Sensor Cable is correctly connected and is NOT damaged.• Check all the tubes of the APS and make sure they are NOT pinched or damaged.• Faulty APS Sensor, APS Valve or APS Motor. Replace the complete APS.• If the error code continues, replace the Electronics Module
Code: 0B000C
Description: Serial Device ADC test failure
Remedy: Replace the Electronics Module
Code: 0B000D
Description: 24 V source test failure.
Remedy: Replace the Electronics Module
Code: 0C0030
Description: Bad Drop Detector.
Remedy: • Check that the Drop Detector Cable is NOT broken or damaged.• Check that the Drop Detector cable is correctly connected to the Service Station Cable.• Remove the Drop Detector and make sure that there are no obstacles inside which are blocking the sensor.• Replace the Drop Detector Assembly.• If the Error Code continues, replace the Electronics Module
Code: 0C0032
Description: Drop Detector not Calibrated for all Printheads.
Remedy: • Perform the Service Station Calibration.• Replace the Drop Detector Assembly.• If the Error Code continues, replace the Electronics Module
Code: 0C1000
Description: Primer not Calibrated.
Remedy: • Perform the Service Station Calibration.• Make sure that the Primer Arm is not damaged. If the Primer Arm is damaged, replace the Service Station.• Replace the Electronics Module.
Code: 0C1001
Description: Primer Shutdown Error.
Remedy: • Check that the Primer Stepper-Motor Cable is NOT broken or damaged and that the Primer arm moves freely from side to side.• Replace the Service Station.• If the Error Code continues, replace the Electronics Module