Remedy: • Check that the cable from the Ink Supply Station (ISS) PCA to the Ink Supply Station is correctly connected.• Faulty APS Pump. Replace the complete APS.• If the error code continues, replace the Electronics Module
Remedy: • Check that the cable from the Ink Supply Station (ISS) PCA to the Ink Supply Station is correctly connected.• Faulty APS Valve. Replace the complete APS.• If the error code continues, replace the Electronics Module
Description: The Trailing Cable has been incorrectly connected OR the fuse in the Electronics Module has been burned.
Remedy: Turn the Printer OFF and disconnect the trailing cable. Check that the ends of the Trailing Cable are flat and are not damaged or bent. Reconnect the Trailing Cable correctly, making sure it is pushed in firmly (Refer to the instructions on Page 8-39). Power ON the Printer and check if the Error Code disappears. If the Error Code continues, replace the Electronics Module (Refer to the instructions on Page 8-25), making sure you take care when you reconnect the Trailing Cable.
Remedy: • Make sure that the Vacuum Fan is connected correctly to the Electronics Module.• Turn the Printer OFF and disconnect the Vacuum Fan from the Electronics Module. Connect a New Vacuum Fan to the Electronics Module and power ON the Printer. If the New Vacuum Fan functions correctly without any Error Codes then remove the Old Vacuum Fan from the Printer and install the New one.• If the New Vacuum Fan does not function correctly either, then replace the Electronics Module.
Description: Unable to detect Aerosol Fan (Included on the Right Cover).
Remedy: • Make sure that the Aerosol Fan is connected correctly to the Electronics Module.• Turn the Printer OFF and disconnect the Aerosol Fan from the Electronics Module. Connect a New Aerosol Fan (comes with the new Right Cover) to the Electronics Module and power ON the Printer. If the New Aerosol Fan functions correctly without any Error Codes then remove the Old Aerosol Fan from the Printer and install the New one.• If the New Aerosol Fan does not function correctly either, then replace the Electronics Module.
Remedy: • Check that the Primer Stepper-Motor Cable is NOT broken or damaged and that the Primer arm moves freely from side to side.• Replace the Service Station.• If the Error Code continues, replace the Electronics Module
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.