  • Code: 14.34:01
  • Description: Pinch Power regulator V lower than 180
  • Causes: Pinch Power regulator V lower than 180.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
  • Code: 14.35:01
  • Description: Pinch Power regulator V higher than Vmax
  • Causes: Pinch Power regulator V higher than Vmax.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
  • Code: 14.36:11
  • Description: Pinch Power regulator V could not be read
  • Causes: Pinch Power regulator V could not be read.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input cables. 3. Replace the control cables to the sine-wave converters.
  • Code: 14.40:10
  • Description: Pinch Power regulator current not null
  • Causes: Pinch Power regulator current not null.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Replace the sine-wave converter. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
  • Code: 14.41:10
  • Description: Pinch Power regulator current too high
  • Causes: Pinch Power regulator current too high.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check heaters with a tester and replace heaters if necessary (short-circuit). 4. Replace the sine-wave converter.
  • Code: 14.42:10
  • Description: Pinch Power regulator short-circuit
  • Causes: Pinch Power regulator short-circuit.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check heaters with a tester and replace heaters if necessary. 4. Replace the sine-wave converter.
  • Code: 14.43:11
  • Description: Pinch Power Regulator open circuit
  • Causes: Pinch Power Regulator open circuit. If the error appears in the middle of a print and recovers after cooling down, it could be caused by an abnormal increase in the drying module temperature leading one of the thermal switches to open. See System Errors 15.03:00 and 15.20:01 for more information.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check cable connections and heaters with a tester. 4. Check the drying module: • Ensure that the heaters do not touch the metal covers at the sides, close to the thermal switches. • Remove the side covers. Ensure that the connections to the thermal switches are strong; tighten the nuts if necessary. In addition, ensure the cables are not peeled or in bad condition. 5. Replace the drying heaters if any of the above applies. Other possible causes: • The room temperature is too high or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, or heaters. • This system error may be caused by a setting in the RIP being used by the customer. If the ¡¥Minimum Drying Power¡¦ setting in the RIP is too high, this can cause the system error to be triggered. Set the Minimum Drying Power to 0, and check whether the error remains. • Check that there are no obstructions on any of the cooling fans: Dryer, Curing, Top Cover Fans, Rear Fans. • Check that all the fans are functioning correctly. Check that the cables of the fans are not damaged and are connected. Replace any fans if required: Top cover fans. Drying Fans. Curing Fans. See System Errors 15.03:00 and 15.20:01 for more information.
  • Code: 14.46:11
  • Description: Pinch Power regulator R out of range
  • Causes: Pinch Power regulator R out of range.
  • Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check cable connections. 4. Check heaters with a tester and replace heaters if necessary. 5. Replace the sine-wave converter.