Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi HP DesignJet L65500 — Trang 5/24

Code: 14.47:10

Description: Pinch Power regulator OverTemp
Causes: Pinch Power regulator OverTemp.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check cable connections. 4. Check that the input voltage is within specifications. 5. Replace the sine-wave converter.

Code: 14.48:10

Description: Pinch Power regulator overvoltage or short-circuit
Causes: Pinch Power regulator overvoltage or short-circuit.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check cable connections. 4. Check that the input voltage is within specifications. 5. Replace the sine-wave converter.

Code: 14.49:10

Description: Pinch sine-wave converter failure
Causes: Pinch sine-wave converter failure.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Replace the sine-wave converter.

Code: 14.51:10

Description: Overdrive power regulator V null and no fault
Causes: Overdrive power regulator V null and no fault.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Replace the control cables to the sine-wave converter.

Code: 14.52:01

Description: Overdrive power regulator V null and fault
Causes: Overdrive power regulator V null and fault.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check the Residual Current Circuit Breakers. 4. Check the input voltage.

Code: 14.53:01

Description: Overdrive power regulator V lower than 140
Causes: Overdrive power regulator V lower than 140.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.

Code: 14.54:01

Description: Overdrive power regulator V lower than 180
Causes: Overdrive power regulator V lower than 180.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.

Code: 14.55:01

Description: Overdrive power regulator V higher than Vmax
Causes: Overdrive power regulator V higher than Vmax.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie