Causes: The array 1 of curing system fans is not connected.
Remedy: Check the cable connections to the curing fans.
Code: 16.09:00
Description: Curing fan array 1 fault
Causes: Curing fan array 1 fault.
Remedy: 1. Run the Diagnostic test and confirm which fans are rotating. 2. If none of the fans is working, replace the PrintMech PCA. 3. Replace the cable from the PrintMech to the fans. 4. If at least one of the fans is working, ensure it is connected to the array 1 cable. 5. Replace the non-rotating fans.
Code: 16.11:00
Description: Curing fans array 2 not connected
Causes: Curing fans array 2 not connected.
Remedy: Check the cable connections to the curing fans array 2.
Code: 16.20:11
Description: IR sensor curing fan not connected
Causes: IR sensor curing fan not connected.
Remedy: Check the cable connections to the IR sensor.
Code: 16.21:10
Description: Curing fan array 2 fault
Causes: Curing fan array 2 fault.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the diagnostic test and confirm which fans are rotating. 3. If none of the fans is working, replace the PrintMech PCA. 4. Replace the cable from the PrintMech PCA to the fans. 5. If at least one of the fans is working, ensure that it is connected to the array 2 cable. 6. Replace the non-rotating fans.
Code: 17.0:11
Description: PrintMech to Interconnect power cable disconnected
Causes: The PrintMech to Interconnect power cable does not seem to be connected.
Remedy: 1. Check that the PrintMech to Interconnect power cable is not damaged. 2. Check that the PrintMech to Interconnect power cable is correctly connected to the PrintMech PCA and the Interconnect PCA. 3. Replace the PrintMech to Interconnect power cable (which is included in the Electronics Module Cable Kit).
Code: 17.1:11
Description: PrintMech to Interconnect data 1 cable disconnected
Causes: The PrintMech to Interconnect data 1 cable does not seem to be connected.
Remedy: 1. Check that the PrintMech to Interconnect data 1 cable is not damaged. 2. Check that the PrintMech to Interconnect data 1 cable is correctly connected to the PrintMech PCA and the Interconnect PCA. 3. Replace the PrintMech to Interconnect data 1 cable.
Code: 17.2:11
Description: PrintMech to Interconnect data 2 cable disconnected
Causes: The PrintMech to Interconnect data 2 cable does not seem to be connected.
Remedy: 1. Check that the PrintMech to Interconnect data 2 cable is not damaged. 2. Check that the PrintMech to Interconnect data 2 cable is correctly connected to the PrintMech PCA and the Interconnect PCA. 3. Replace the PrintMech to Interconnect data 2 cable.