Code: 59.00.YY

Display: 59.00.YY Error
Description: Fuser motor (M2) start up error or fuser motor (M2) rotational error: pressure roller, delivery roller, fuser pressurization, primary transfer roller disengagement.
Remedy:

Code: 59.05.06

Display: 59.05.06
Description:
Remedy: 1. Turn the product off, and then on. 2. Check the connector (J121) on the DC controller PCA. 3. Use the motor drive test in the component tests to verify that the motor is properly functioning. If it is not, replace the drum motor (M3).

Code: 59.05.07

Display: 59.05.07
Description:
Remedy: 1. Turn the product off, and then on. 2. Check the connector (J121) on the DC controller PCA. 3. Use the motor drive test in the component tests to verify that the motor is properly functioning. If it is not, replace the drum motor (M3).

Code: 59.05.08

Display: 59.05.08
Description:
Remedy: 1. Turn the product off, and then on. 2. Check the connector (J120) on the DC controller PCA. 3. Use the motor drive test in the component tests to verify that the motor is properly functioning. If it is not, replace the drum motor (M1).

Code: 59.05.09

Display: 59.05.09
Description:
Remedy: 1. Turn the product off, and then on. 2. Check the connector (J120) on the DC controller PCA. 3. Use the motor drive test in the component tests to verify that the motor is properly functioning. If it is not, replace the drum motor (M1).

Code: 59.05.10

Display: 59.05.10
Description:
Remedy: 1. Turn the product off, and then on. 2. Check the connector (J120) on the DC controller PCA. 3. Use the motor drive test in the component tests to verify that the motor is properly functioning. If it is not, replace the drum motor (M1).

Code: 59.05.11

Display: 59.05.11
Description:
Remedy: 1. Turn the product off, and then on. 2. Check the connector (J120) on the DC controller PCA. 3. Use the motor drive test in the component tests to verify that the motor is properly functioning. If it is not, replace the drum motor (M1).

Code: 59.05.12

Display: 59.05.12
Description:
Remedy: 1. Turn the product off, and then on. 2. Check the connector (J120) on the DC controller PCA. 3. Use the motor drive test in the component tests to verify that the motor is properly functioning. If it is not, developing disengagement motor (M10). 4. Use the manual sensor test to verify that the ITB alienation sensor (SR17) is properly functioning. If it is not, replace the ITB alienation sensor (SR17).
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie